Romberg ratio in quiet stance posturography--Test to retest reliability.
نویسندگان
چکیده
UNLABELLED We investigated test to retest reliability and intraindividual variability of Romberg ratios in quiet stance posturography. Thirty-six healthy young adults (17 males, 19 females aged 15-38 years) were divided into 3 groups with different time-intervals between consecutive trials (20 min, 3h and 24h respectively). Each group performed 5 posturography recordings in a randomized order of eyes open (EO) or closed (EC)+once after 3 months. We measured the torque variance in posturography and calculated Romberg ratios. Total postural sway as well as sway above and below 0.1Hz was analyzed. RESULTS Test to retest reliability was found to be poor for Romberg ratios (intraclass correlation coefficients (ICC) <0.4) despite that the individual EO and EC posturography recordings were consistent. For sway >0.1Hz the Romberg ratios were found to be more consistent (fair to good, ICC 0.49-0.71). The variation between two consecutive tests (absolute difference (%)) was high when using the traditional Romberg ratio (EC/EO), but became less varied if an alternate formula that includes the total postural sway was used ((EC-EO)/(EC+EO)×100). CONCLUSION In healthy young adults the evaluation of ratios from repeated quiet stance posturography show great intraindividual inconsistency. This questions the Romberg ratio as being a reliable tool for evaluation of postural performance and determination of sensory preference in postural control, at least in healthy controls. Whether test-retest reliability is acceptable in patient cohorts needs to be evaluated for proper validity of intervention and outcome studies and for detection of clinical relevance.
منابع مشابه
Test-retest reliability and minimal detectable change for center of pressure measures of postural stability in elderly subjects
Abstract Background: Postural instability has been identified as a potential precursor of falls in elderly subjects. Postural stability in quiet stance is commonly assessed with center of pressure (COP) measures. The purpose of this study was to determine testretest reliability and minimal detectable change (MDC) for the center of pressure (COP) measures in the elderly subjects. Met...
متن کاملTest-Retest Reliability of Measurements of the Center of Pressure Displacement in Quiet Standing and During Maximal Voluntary Body Leaning Among Healthy Elderly Men
The aim of the study was to evaluate intra- and intersession test-retest reliability for the measurements of centre of pressure displacement in quiet standing and during maximal voluntary body leaning (approximate area of stability limits). 27 elderly men participated in the study (71.4±4.9 of age). Intrasession (4 measurements with two-minute breaks) and intersession (4 measurements one week a...
متن کامل[Cross-cultural adaptation and validation of the Dizziness Handicap Inventory: Argentine version].
INTRODUCTION AND OBJECTIVES The Dizziness Handicap Inventory is a useful tool for quantifying self-perceived handicap in patients with vertigo, dizziness or unsteadiness and its impact on daily living activities. The Dizziness Handicap Inventory identifies functional, physical and emotional disorders related to balance disturbance. Our objective was to cross-culturally adapt the Peninsular Span...
متن کاملBalance in single-limb stance in healthy subjects – reliability of testing procedure and the effect of short-duration sub-maximal cycling
BACKGROUND To assess balance in single-limb stance, center of pressure movements can be registered by stabilometry with force platforms. This can be used for evaluation of injuries to the lower extremities. It is important to ensure that the assessment tools we use in the clinical setting and in research have minimal measurement error. Previous studies have shown that the ability to maintain st...
متن کاملReliability and validity of judgments of sound quality in elderly hearing aid wearers.
OBJECTIVE The aim of the present study was to evaluate a particular sound-quality rating procedure, referred to here as the Judgments of Sound Quality (JSQ) test, for potential use as an outcome measure with elderly hearing aid wearers. The validity and reliability of the JSQ as an outcome measure were determined for unaided and aided listening conditions. DESIGN A repeated-measures design wa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Gait & posture
دوره 42 1 شماره
صفحات -
تاریخ انتشار 2015