Assessing the deviation from the inverse square law for orthovoltage beams with closed‐ended applicators
نویسندگان
چکیده
In this report, we quantify the divergence from the inverse square law (ISL) of the beam output as a function of distance (standoff) from closed-ended applicators for a modern clinical orthovoltage unit. The divergence is clinically significant exceeding 3% at a 1.2 cm distance for 4 × 4 and 10 × 10 cm2 closed-ended applicators. For all investigated cases, the measured dose falloff is more rapid than that predicted by the ISL and, therefore, causes a systematic underdose when using the ISL for dose calculations at extended SSD. The observed divergence from the ISL in closed-ended applicators can be explained by the end-plate scattering contribution not accounted for in the ISL calculation. The standoff measurements were also compared to the predictions from a home-built kV dose computation algorithm, kVDoseCalc. The kVDoseCalc computation predicted a more rapid falloff with distance than observed experimentally. The computation and measurements agree to within 1.1% for standoff distances of 3 cm or less for 4 × 4 cm2 and 10 × 10 cm2 field sizes. The overall agreement is within 2.3% for all field sizes and standoff distances measured. No significant deviation from the ISL was observed for open-ended applicators for standoff distances up to 10 cm.
منابع مشابه
Role of in vivo dosimetry with radiochromic films for dose verification during cutaneous radiation therapy
PURPOSE To evaluate the role of in vivo dosimetry with radiochromic films for dose verification in cutaneous radiation therapy (RT). METHODS Five patients with 8 cutaneous or sub-cutaneous malignancies of the face, neck, trunk and extremity receiving RT were included. Orthovoltage, megavoltage photon therapies were applied based on anatomic location. The delivered dose for each target was mea...
متن کاملBehavior correction of the inverse square law in irradiation room for volumetric source and detector
The inverse-square law is used to calculate the radiation flux at difference distances from the source. This law is applied for point source and point detector in vacuum. This research aims to study the point behavior of volumetric source and detector by undertaking required corrections on inverse-square law through the elimination of scattered neutrons contribution. The measurements have been ...
متن کاملOn Static Bending, Elastic Buckling and Free Vibration Analysis of Symmetric Functionally Graded Sandwich Beams
This article presents Navier type closed-form solutions for static bending, elastic buckling and free vibration analysis of symmetric functionally graded (FG) sandwich beams using a hyperbolic shear deformation theory. The beam has FG skins and isotropic core. Material properties of FG skins are varied through the thickness according to the power law distribution. The present theory accounts fo...
متن کاملMonte Carlo Simulation of Electron Beams produced by LIAC Intraoperative Radiation Therapy Accelerator
Background: One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry.Materials and Methods: Liac accelerator head was modeled using the BEAMnrcMonte Carlo simulation system. Phase-space files were generated at...
متن کاملA Simple Approach to Predict the Shear Capacity and Failure Mode of Fix-ended Reinforced Concrete Deep Beams based on Experimental Study
Reinforced Concrete (RC) deep beams are commonly used in structural design to transfer vertical loads when there is a vertical discontinuity in the load path. Due to their deep geometry, the force distribution within the RC deep beams is very different than the RC shallow beams. There are some strut and tie model (STM) already been developed for RC deep beams. However, most of these models are ...
متن کامل