Variation in nebulizer aerosol output and weight output from the Mefar dosimeter: implications for multicentre studies.

نویسندگان

  • S Chinn
  • W A Arossa
  • D L Jarvis
  • C M Luczynska
  • P G Burney
چکیده

The active aerosol component of nebulizers is less than 100% of output by weight, and may vary between nebulizers in different batches from the same manufacturer. A measure of bronchial responsiveness to methacholine, which can overcome this problem, is required. One hundred and sixty nebulizers from 21 centres in the European Community Respiratory Health Survey (ECRHS) were calibrated for aerosol and weight output. Methacholine challenge data were obtained for 1,021 subjects in three English centres of the ECRHS. The dose producing a 20% fall in forced expiratory volume in one second (PD20), and log-slope, the regression slope of percentage decline in FEV1 with log (dose), were calculated, with and without calibration of nebulizers by weight. Within-centre variation in nebulizer percentage aerosol output had a coefficient of variation of less than 10%. Unlike PD20, log-slope is unaffected by constant percentage overestimation of nebulizer output. Variation in output by weight of nebulizers of 10% had little affect on log-slope. It is, however, affected by the scheduled range of doses. Log-slope shows advantages in analysis, and is less affected by variation in nebulizer output. It can be used for multicentre comparisons, with restriction to a common dose protocol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variation in nebulizer output and weight output from Mefar dosimeter: implications for multicentre studies.

We wish to comment upon the paper of CHINN et al. [1] in which both weight and aerosol output data were given for 193 Mefar nebulizers from 27 centres involved in the European Community Respiratory Health Survey (ECRHS). A single centre in Turin determined nebulizer output using the sodium fluoride (NaF) tracer method described by DENNIS et al. [2]. The weight output was given as 11 mg·s-1 with...

متن کامل

Calibration of aerosol output from the Mefar dosimeter: implications for epidemiological studies.

Standardized methods for the measurement of airway responsiveness may use the Mefar MB3 inhalation dosimeter to generate standard doses of methacholine aerosol. The manufacturer provides calibrated output data for every nebulizer, so that a standard output may be achieved by varying nebulization time. This output is, however, measured by weight loss (WL), which may over-estimate true aerosol ou...

متن کامل

A critical evaluation of the Mefar dosimeter.

Multicentre studies of airway responsiveness (AR) are increasingly important tools in asthma epidemiology. Because comparisons of AR are made between centres it is essential that measurement techniques are accurate and standard. This study investigated the Mefar dosimeter which is currently used in the 35 centre European Community Respiratory Health Survey (ECRHS) with the next phase currently ...

متن کامل

A new method for measuring aerosol nebulizer output using radioactive tracers.

Reproducibility and comparability of bronchial challenge tests depends critically on accurate assessment of nebulizer output. Evaporation during nebulization means that simple weighing is inaccurate, overestimating the delivered dose of active ingredient. We wanted to quantify this effect in the context of intermittent nebulization, using a dosimeter as used in bronchial provocation tests. Outp...

متن کامل

Nebulizer calibration using lithium chloride: an accurate, reproducible and user-friendly method.

Conventional gravimetric (weight loss) calibration of jet nebulizers overestimates their aerosol output by up to 80% due to unaccounted evaporative loss. We examined two methods of measuring true aerosol output from jet nebulizers. A new adaptation of a widely available clinical assay for lithium (determined by flame photometry, LiCl method) was compared to an existing electrochemical method ba...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 10 2  شماره 

صفحات  -

تاریخ انتشار 1997