Layered Shielding Design for Pet Clinics

نویسندگان

  • Robert L. Metzger
  • Kenneth A. Van Riper
چکیده

The number of Positron Emission Tomography (PET) centers has been growing rapidly. Many of the new facilities have been retrofitted into existing imaging centers and hospitals. Space in the facilities is often cramped, resulting in the hot lab, patient quiet rooms, and the scanners frequently being placed in close proximity to uncontrolled areas where non-occupational dose limits apply. Of particular concern are ceilings when occupied areas are above the PET clinics. Ceiling shielding is generally constructed of layers of suspended lead, steel, and the existing concrete floor of the deck above. The attenuation provided the layered shield is difficult to calculate by point kernel techniques, yet the cost of overshielding can be high when lead must be suspended from the floor above. In this work we evaluate ceiling shielding for a proposed PET center using different methods. A Monte Carlo calculation using MCNP modeled the patient with a sitting MIRD anthropomorphic model in which 15 mCi of FDG is distributed equally among the brain and 18 bladder. A point kernel calculation was made using Mercurad, a code designed to manage attenuation in layered shields. The results from the two models are compared to each other and to measurements conducted on the finished PET clinic.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Attenuation Coefficients for Layered Ceiling and Floor Shields in PET/CT Clinics

INTRODUCTION Positron Emission Tomography (PET) is enjoying explosive growth due to its ability to accurately stage many types of cancer and follow the progress of treatments. The facilities present unique challenges in shielding design due to the nature of the study, and the desire to place the facilities near other imaging and treatment clinics. A typical PET patient will receive 555 MBq (15 ...

متن کامل

A Monte Carlo shielding model for PET/CT clinics

A Monte Carlo shielding model for PET/CT clinics Robert L. Metzger and Kenneth A. Van Riper Radiation Safety Engineering, Inc Chandler, AZ Abstract Modern PET/CT clinics consist of a scanner room housing the double gantry PET/CT unit and a control area, two or more quiet rooms where patients rest prior to scanning, and a hot lab where doses are prepared. Of these areas, the scanner room, quiet ...

متن کامل

A Comparative Study of the Construction of Positron Emission Tomography/Computed Tomography Facilities in Three South African Hospitals

Introduction: Development of higher energy modalities such as positron emission tomography/computed tomography (PET/CT), has led to more complex shielding problems. This is due to several factors, such as the radiopharmaceutical relatively high-administered activity, high patient throughput, and high energies of 511 kilo-electron volt (keV) positron annihilation photon...

متن کامل

Optimum shielding structure for the wall of medical LINAC facility

When considering the space limit of high energy LINAC facility in a hospital, the design of shielding wall is strongly required to optimize the wall thickness. Shielding wall usually consists of concrete, and iron plate is sometimes added in concrete to decrease the wall thickness. We investigated the optimum design of the shielding wall in medical LINAC facility by simulation. The calculations...

متن کامل

Design of Light Multi-layered Shields for Use in Diagnostic Radiology and Nuclear Medicine via MCNP5 Monte Carlo Code

Introduction Lead-based shields are the most widely used attenuators in X-ray and gamma ray fields. The heavy weight, toxicity and corrosion of lead have led researchers towards the development of non-lead shields. Materials and Methods The purpose of this study was to design multi-layered shields for protection against X-rays and gamma rays in diagnostic radiology and nuclear medicine. In this...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005