Pii: S1010-7940(02)00066-0
نویسندگان
چکیده
Background: While morphologic integration of transplanted fetal cardiomyocytes into the ventricular myocardium is a well-known fact, no studies have yet shown transplanted cells to coherently contribute to contraction and electrical excitation of the host myocardium. The aim of this study was to prove the hypothesis that by transplanting cardiomyocytes with a higher intrinsic rhythmic rate into the myocardium of the left ventricle, these cells could act as an ectopic pacemaker by functional coupling with host cardiomyocytes. Methods and Results: Dissociated fetal canine atrial cardiomyocytes including sinus nodal cells were delivered into the free wall of the left ventricle of adult canine X-linked muscular dystrophy dogs (n 1⁄4 2). These dogs fail to express Dystrophin in both cardiac and skeletal muscle. In the control group (n 1⁄4 2) fetal skin fibroblasts were used for grafting. A total of 3–4 weeks after transplantation the dogs underwent catheter ablation of the atrioventricular node (AV-node) and subsequent electrophysiological mapping studies. Transplanted cells were identified by Dystrophin immunoreactivity, indicating survival and morphological integration in the recipient heart. The expression of Connexin 43 between donor and recipient cells suggested formation of gap junctions between injected and host cardiomyocytes. After catheter ablation of the AV-node, a ventricular escape rhythm emerged driving the pace of the heart and originating from the labeled transplantation site. This effect could not be observed in the control group (n 1⁄4 2). Conclusions: The results constitute the first observation of phenomena indicating electrical and mechanical coupling between allogeneic donor cardiomyocytes and recipient myocardium in-vivo. Further experiments are necessary to evaluate the technique as a potential therapy for atrioventricular block. q 2002 Elsevier Science B.V. All rights reserved.
منابع مشابه
Pii: S1010-7940(02)00020-9
Electrocautery has a potential risk of serious pacemaker dysfunction in patients with implanted pacemaker. Here we present the safe and efficient use of ultrasonic scalpel (Harmonic scalpel) for the first time in a patient with implanted pacemaker undergoing open-heart reoperation. q 2002 Elsevier Science B.V. All rights reserved.
متن کاملPii: S1010-7940(02)00664-4
This report describes the formation of a true aneurysm 15 years after an internal mammary artery patch aortoplasty of an aortic coarctation. A true aneurysm was confirmed on histology. To our knowledge, this is the first report of a case with such a complication. q 2002 Published by Elsevier Science B.V.
متن کاملPii: S1010-7940(02)00369-x
Lipomatous hypertrophy of the interatrial septum is an uncommon entity that usually occurs in elderly patients. We report a patient who presented with atrial fibrillation, congestive cardiac failure and a large intracavitary mass in the right atrium on echocardiography. He underwent successful resection of the mass with septal reconstruction. Pathology was consistent with lipomatous hypertrophy...
متن کاملPii: S1010-7940(02)00349-4
Arterial pseudoaneurysm has been reported as a possible complication of immunodeficiency virus infection. We report two cases of HIVpositive patients with a pseudoaneurysm at the level of the descending thoracic aorta. The first patient refused surgery and has been followed up to 14 months, whereas the second patient underwent successful surgical repair. The importance of magnetic resonance ima...
متن کاملPii: S1010-7940(02)00396-2
We present rupture of lung hydatid cyst in a patient with multiple organ involvement during albendazole treatment. The patient was first provided mechanical ventilation than residue cavity and the other intact cyst was treated surgically. We concluded that albendazole should be used in postoperative period in patients with hydatid disease of the lung to prevent recurrent disease. q 2002 Elsevie...
متن کاملPii: S1010-7940(02)00724-8
Aortobronchial fistula is a rare complication following thoracic aortic operations and is invariably fatal if not promptly diagnosed and repaired. Direct prosthetic repair carries a risk of graft repair sepsis and fistula recurrence. We describe two cases presenting with aortobronchial fistula following coarctation repair which were successfully treated by different surgical approaches. q 2002 ...
متن کامل