Comparative Study on the Surface Dose of Some Bolus Materials
نویسندگان
چکیده
In order to investigate the possibility of using different materials as bolus in radiotherapy, five samples denoted by S2 S6 were prepared and analyzed by comparison with one available commercial bolus denoted by S1. Sample S1 was a thermoplastic material from Qfix; S2 was a moldable silicon rubber (RTV-530 from Prochima); S3 and S4 were obtained by adding micrometric particles of Al and Cu respectively (at the same mass concentration of 5.5%); S5 was another moldable silicon rubber (GSP400 from Prochima) and S6 was a mixture of GSP400 and micrometric particles of Cu (at the mass concentration of 5.5%). The measurements of normalized transmitted dose as a function of sample thickness were performed for all samples (S1 S6) at two values of electron beam energy (6 and 9 MeV) produced by a linear accelerator VARIAN 2100SC. The results showed that the maximum of the normalized transmitted dose of manufactured samples (S2 S6) is registered at smaller sample thicknesses than for the analyzed commercial bolus (sample S1). The smallest sample thickness corresponding to normalized maximum point dose is obtained for sample S2 (RTV-530). Measurements performed for electron beam energy of 6 and 9 MeV have proven the possibility of using the manufactured samples as bolus in radiotherapy.
منابع مشابه
Calculation of air gaps between bolus and skin on the dose received from the skin
Introduction: In the last few decades, a lot of monte carlo codes have been introduced for medical applications. For close - to - surface tumors, the surface of the skin can be used to increase the surface dose so that all or part of the bunch area can fall into bolus, thereby increasing the dose of the skin. The air gaps between bolus and skin can affect the dose of...
متن کاملEvaluating the performance of a 3D PLA buildup bolus in breast intraoperative radiotherapy.
Introduction: The received dose to the surface of tumor bed is one of the main issues in beast intraopeative radiotherapy (IORT). Totally, the administered dose to the surface is usually lower than that of radiotherapy reference point (distal end of tumor bed). Employing a buildup bolus can effectively increase the surface dose and therefore, eliminate such created cold points ...
متن کاملTelecobalt Machine Beam Intensity Modulation with Aluminium Compensating Filter Using Missing Tissue Approach
Introduction: The present study aimed to generate intensity-modulated beams with Aluminium compensating filters for a conventional telecobalt machine based on the outputs of a treatment planning system (TPS) performing forward planning and cannot simulate directly the compensating filter. Materials and Methods: In order to achieve the beam intensity modulation during treatment planning with th...
متن کاملOn Presentation of Optimal Treatment Plan in Radiotherapy of Parotid Cancer: A Comparison of Nine Techniques in Three Dimensional Conformal Radiation Therapy
Introduction: Today, radiotherapy combined with surgery in the treatment of parotid tumors widely are used specially for high grade parotid tumors. One of concern and challenge issue of radiotherapy is that the treatment of these tumors with irregular surface due to the presence of external ear and region of different physical electron density (air cavities, dense bone, soft t...
متن کاملPhysical Properties of Ethyl Methacrylate as a Bolus in Radiotherapy
Introduction Bolus is a soft and resilient material which is used for increasing skin dose or to even out the irregular patient contour. The main property of various materials used presently as bolus is the water-equivalent electron density. Ethyl methacrylate is used as a soft-liner in dentistry and its physical and chemical properties are proved to be nontoxic for human body. The goal of this...
متن کامل