Imprecision of quantification of serum protein fractions by electrophoresis on cellulose acetate.
نویسندگان
چکیده
We studied the precision of densitometric quantification of the protein zones resolved by cellulose acetate electrophoresis. Replicate analyses of patients' samples by a single technologist showed mean CVs ranging from 2.9% for serum albumin to 9.5% for alpha 1-globulin. There were marked differences in measurements obtained by replicate analysis of the same samples by two experienced technologists. We calculated what changes in fractional concentrations would be analytically significant and concluded that densitometry of cellulose acetate electrophoretograms can only be semi-quantitative. We suggest that visual interpretation of high-resolution electrophoretic patterns by a trained observer can replace densitometry in most cases.
منابع مشابه
Serum protein fractions as determined by cellulose actate electrophoresis in schistosoma mattheei infested sheep.
VAN ZYL, LULU C. , 1974. Serum protein fractions as determined by cellulose acetate electrophoresis in Schistosoma mattheei infested sheep. Onderstepoort J. vet . Res. 41, 714 (1974). The serum protein fraction values of Dorper sheep infested with Schistosoma mattheei were determined by cellulose acetate electrophoresis at regular intervals for 15 months. Statistical analyses showed that increa...
متن کاملRapid cellulose acetate electrophoresis. I. Serum proteins.
A method of electrophoresis utilizing cellulose acetate is described wherein quantitation of serum protein fractions by densitometry is accomplished within 2 hr. of initiation of the procedure. The densitometer was found to have a linear response to amido black dye. Albumin and y-globulin demonstrated equal dye-binding characteristics. Combined with the absence of albumin trailing, this has aff...
متن کاملEvaluation of a cellulose-acetate electrophoresis system for serum protein fractionation.
A rapid system for the quantitative fractionation of serum proteins by electrophoresis on cellulose-acetate membranes was evaluated and found to be quite precise. The reproducibility (coefficient of variation) of the routine fractionation of a control serum carried out 40 times during a 15-week period was 2.4% for albumin and 14.2, 6.0, 6.1, and 5.2%, respectively, for the ar-, a2-, /3-, and -y...
متن کاملDetection of cryoglobulins in serum of Caspian miniature horse
Blood samples were collected from 20 healthy miniature Caspian horses at 37 °C. Isolation of cryoglobulin was performed based on a standard method in present study. Harvested sera were kept at 4 °C for two hours and then examined for cryoglubolin. Four serum samples containing precipitate Suspicious of containing cryoglobulin were selected. Subsequently serum protein electrophoresis was perform...
متن کاملSerum protein electrophoresis and immunofixation by a semiautomated electrophoresis system.
Semiautomated agarose electrophoresis and immunofixation performed with Hydrasys-Hyrys (Sebia) were compared with conventional, manually performed methods, including cellulose acetate electrophoresis, immunoelectrophoresis, and immunofixation. Reference intervals for agarose electrophoresis with Hydrasys-Hyrys were determined. Within-run imprecision (CV) for fraction quantitation with the semia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 32 2 شماره
صفحات -
تاریخ انتشار 1986