Coil-reinforced hydrogel tubes promote nerve regeneration equivalent to that of nerve autografts.

نویسندگان

  • Yusuke Katayama
  • Rivelino Montenegro
  • Thomas Freier
  • Rajiv Midha
  • Jason S Belkas
  • Molly S Shoichet
چکیده

Despite spontaneous sprouting of peripheral axons after transection injury, peripheral regeneration is incomplete and limited to short gaps, even with the use of autograft tissue, which is considered to be the "gold" standard. In an attempt to obviate some of the problems associated with autografts, including limited donor tissue and donor site morbidity, we aimed to synthesize a synthetic nerve guidance channel that would perform as well as the nerve autograft. Given that the patency of the nerve guidance channel is critical for repair, we investigated a series of nerve guidance channel designs where patency and the resulting regenerative capacity were compared in a transected rat sciatic nerve injury model. Three tube designs were compared to autograft tissue: plain, corrugated and coil-reinforced tubes of poly(2-hydroxyethyl methacrylate-co-methyl methacrylate). Of the three designs, the coil-reinforced tubes demonstrated superior performance in terms of patency. By electrophysiology and histomorphometry, the coil-reinforced tubes demonstrated outcomes that were comparable to autografts after both 8 and 16 weeks of implantation. The nerve action potential (NAP) velocity and muscle action potential (MAP) velocity for the coil-reinforced PHEMA-MMA tube was 54.6+/-10.1 and 10.9+/-1.3 m/s, respectively at 16 weeks, which was statistically equivalent to those of the autograft at 37.5+/-7.9 and 11.3+/-2.0 m/s. The axon density in the coil-reinforced tube was 2.16+/-0.61x10(4) axons/mm2, which was statistically similar to that of the autograft of 2.41+/-0.62x10(4) axons/mm2 at 16 weeks. These coil-reinforced tubes demonstrated equivalence to autografts for nerve regeneration, demonstrating the importance of channel design to regenerative capacity and more specifically the impact of patency to regeneration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peripheral nerve regeneration through a synthetic hydrogel nerve tube.

PURPOSE As alternatives to nerve grafts for peripheral nerve repair, we have synthesized 12 mm long poly(2-hydroxyethyl methacrylate-co-methyl methacrylate) (PHEMA-MMA) porous tubes and studied their regenerative capacity for the repair of surgically-created 10 mm rat sciatic nerve gaps. We compared the in vivo regenerative efficacy of these artificial tubes with the gold standard, the nerve au...

متن کامل

Growth factor enhancement of peripheral nerve regeneration through a novel synthetic hydrogel tube.

OBJECT The authors' long-term goal is repair of peripheral nerve injuries by using synthetic nerve guidance devices that improve both regeneration and functional outcome relative to an autograft. They report the in vitro processing and in vivo application of synthetic hydrogel tubes that are filled with collagen gel impregnated with growth factors. METHODS Poly(2-hydroxyethyl methacrylate-co-...

متن کامل

Peripheral nerve regeneration using a keratin-based scaffold: long-term functional and histological outcomes in a mouse model.

PURPOSE The management of peripheral nerve injuries with segmental defects is a challenge to both patient and surgeon. Repairs under tension have a poor prognosis; sensory nerve allografts have donor site morbidity and suboptimal motor recovery, but remain the gold standard. The development of conduit-based repair strategies has evolved and these are promising for sensory nerves and short defec...

متن کامل

Syngeneic Schwann cells derived from adult nerves seeded in semipermeable guidance channels enhance peripheral nerve regeneration.

At present, clinical strategies to repair injured peripheral nerve concentrate on efforts to attain primary suture of the cut nerve ends. If this is not possible, autografts are used to unite the separated nerve segments. Both strategies are based on the recognition that the Schwann cells resident in the peripheral nerve trunk play a crucial role in the regenerative process. Neither strategy ma...

متن کامل

نقش ماتریکس خارج سلولی در فرآیند ترمیم اعصاب محیطی

In severe injuries that led to the destruction of peripheral nerve, repair cannot be spontaneously carried out and medical intervention is required for successful regeneration of damaged nerve. In these cases, the common treatment method is use of nerve autografts, whereas this method has many limitations, nerve regeneration researchers seek to provide alternative methods. So far, one of the im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomaterials

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 2006