Biomechanical evaluation of oversized drilling technique on primary implant stability measured by insertion torque and resonance frequency analysis

نویسندگان

  • Gorka Santamaría-Arrieta
  • Aritza Brizuela-Velasco
  • Felipe J. Fernández-González
  • David Chávarri-Prado
  • Yelko Chento-Valiente
  • Eneko Solaberrieta
  • Markel Diéguez-Pereira
  • José-Antonio Vega
  • Jaime Yurrebaso-Asúa
چکیده

BACKGROUND This study evaluated the influence of implant site preparation depth on primary stability measured by insertion torque and resonance frequency analysis (RFA). MATERIAL AND METHODS Thirty-two implant sites were prepared in eight veal rib blocks. Sixteen sites were prepared using the conventional drilling sequence recommended by the manufacturer to a working depth of 10mm. The remaining 16 sites were prepared using an oversize drilling technique (overpreparation) to a working depth of 12mm. Bone density was determined using cone beam computerized tomography (CBCT). The implants were placed and primary stability was measured by two methods: insertion torque (Ncm), and RFA (implant stability quotient [ISQ]). RESULTS The highest torque values were achieved by the conventional drilling technique (10mm). The ANOVA test confirmed that there was a significant correlation between torque and drilling depth (p<0.05). However, no statistically significant differences were obtained between ISQ values at 10 or 12 mm drilling depths (p>0.05) at either measurement direction (cortical and medullar). No statistical relation between torque and ISQ values was identified, or between bone density and primary stability (p >0.05). CONCLUSIONS Vertical overpreparation of the implant bed will obtain lower insertion torque values, but does not produce statistically significant differences in ISQ values. KEY WORDS Implant stability quotient, overdrilling, primary stability, resonance frequency analysis, torque.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relation between bone density and primary implant stability.

AIMS This study aims to relate bone density in Hounsfield units (Hu) with the primary implant stability measured by insertion torque (Ncm) and resonance frequency analysis (ISQ). MATERIALS AND METHODS Ten patients were included in this study. A total of 54 implant sites were provided from 10 computerized tomography scans. The computerized tomography scan was used for the preoperative evaluati...

متن کامل

Biomechanical aspects of primary implant stability: a human cadaver study.

BACKGROUND The quality of bone is an important factor in the successful implant treatment, and it is evident that higher implant failure is more likely in poor quality of bone. The primary stability of oral implants related to resistance to micromotion during healing is influenced by bone quality, surgical technique, and implant design. PURPOSES The aims of this biomechanical study were to ex...

متن کامل

Does Countersinking Improve Implant Primary Stability in Low Density Bone?

ABSTRACT In order to evaluate the effect of countersinking on dental implants primary stability installed in low density bones, thirty dental implants were installed in the most proximal region of oxen ribs and grouped as follow: Group1: Fifteen implants installed by standard drilling with countersinking, Group2: Fifteen implants installed by standard drilling without countersinking. The gradua...

متن کامل

Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications.

Osseointegrated implants for prosthetic rehabilitation of the edentulous patient show high success rates if certain preconditions are fulfilled. Implant stability plays a critical role for a successful critical outcome since short implants and implants placed in soft bone are more prone to failure (13, 49). In the original protocols for implant placement, primary implant stability was ensured b...

متن کامل

Biomechanical evaluation of dental implants with different surfaces: Removal torque and resonance frequency analysis in rabbits

STATEMENT OF PROBLEM Macroscopic and especially microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Dental implants with modified surfaces have shown stronger osseointegration than implants which are only turned (machined). Advanced surface modification techniques such as anodic oxidation and Ca-P application have been developed to achieve fas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2016