Qualification of the FFT spectrometer Phoenix-3

نویسندگان

  • Christian A. Monstein
  • Hansueli Meyer
  • Andreas James
چکیده

Phoenix-3 based on a commercially available FFT spectrometer board AC-240, connected to a broadband receiver was qualified to be used as a solar polarization spectrometer. A pile of very time consuming measurements showed, that the system fulfills the given requirements to observe solar radiation between 1GHz and 5GHz in two polarizations. The total of 65536 channels produces 65 times more data compared to the existing 1000 channels of Phoenix-2. The total bandwidth is comparable with Phoenix-2 but time resolution is much better than Phoenix-2. The radiometric sensitivity is also sightly better than Phoenix-2 due the fact that all samples are integrated on board of the FFT FPGA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving the RX Anomaly Detection Algorithm for Hyperspectral Images using FFT

Anomaly Detection (AD) has recently become an important application of target detection in hyperspectral images. The Reed-Xialoi (RX) is the most widely used AD algorithm that suffers from “small sample size” problem. The best solution for this problem is to use Dimensionality Reduction (DR) techniques as a pre-processing step for RX detector. Using this method not only improves the detection p...

متن کامل

Phoenix-2: a New Broadband Spectrometer for Deci- Metric and Microwave Radio Bursts First Results

A broadband radio spectrometer has been put into operation at Bleien, Switzerland, to register the are emission of the full sun. In the frequency range of operation, 0.1 to 4.0 GHz, both modes of circular polarization are recorded continuously. The new system, Phoenix-2, has been developed from the experience with the previous Phoenix spectrometer. Improved, computer controlled focal hardware a...

متن کامل

PHOENIX A New Broadband Spectrometer for Deci metric and Microwave Radio Bursts First Results

A broadband radio spectrometer has been put into operation at Bleien Switzerland to register the are emission of the full sun In the frequency range of operation to GHz both modes of circular polarization are recorded contin uously The new system Phoenix has been developed from the experience with the previous Phoenix spectrometer Improved computer controlled focal hardware allows now a complet...

متن کامل

A Double FFT Procedure to Improve the Sensitivity of a Tunable Diode Laser Open Path Spectrometer for Sensing Local Atmospheric Gas Concentrations on Mars

A double FFT procedure is developed to improve the sensitivity of a spectrometer to measure atmospheric gases. Simulations show the DFFT reduces the effects of 1/f noise and increase the sensitivity of the measurement. OCIS codes: (280.1100) Aerosol detection; (300.6260) Spectroscopy, diode lasers.

متن کامل

Mineralogy of the Phoenix Landing Sites from the Omega-mex Imaging Spectrometer

Introduction: OMEGA-MEx has targeted the three PHOENIX landing sites during the early 2004 summer (Ls=90°-110°). Amongst the primary goals of these observations, there were to detect water ice exposures, identify the presence of altered minerals such as phyllosilicates and/or sulfates, estimate the surface hydration, and check anomalies in the thermal properties. The results for the three landi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009