Real-time restoration of white-light confocal microscope optical sections

نویسندگان

  • Madhusudhanan Balasubramanian
  • S. Sitharama Iyengar
  • Roger W. Beuerman
  • Juan Reynaud
  • Peter R. Wolenski
چکیده

Confocal microscopes (CM) are routinely used for building 3-D images of microscopic structures. Nonideal imaging conditions in a white-light CM introduce additive noise and blur. The optical section images need to be restored prior to quantitative analysis. We present an adaptive noise filtering technique using Karhunen-Loéve expansion (KLE) by the method of snapshots and a ringing metric to quantify the ringing artifacts introduced in the images restored at various iterations of iterative Lucy-Richardson deconvolution algorithm. The KLE provides a set of basis functions that comprise the optimal linear basis for an ensemble of empirical observations. We show that most of the noise in the scene can be removed by reconstructing the images using the KLE basis vector with the largest eigenvalue. The prefiltering scheme presented is faster and does not require prior knowledge about image noise. Optical sections processed using the KLE prefilter can be restored using a simple inverse restoration algorithm; thus, the methodology is suitable for real-time image restoration applications. The KLE image prefilter outperforms the temporal-average prefilter in restoring CM optical sections. The ringing metric developed uses simple binary morphological operations to quantify the ringing artifacts and confirms with the visual observation of ringing artifacts in the restored images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Confocal White Light Microscopy

Non-contact optical techniques for 3D surface data acquisition like short coherence (white light) interferometry, optical profilers or fringe projection are well established for applications with low surface complexity, where the average surface roughness amplitude is small and neglectable compared to the form amplitudes or where the aspect ratios of amplitudes and spacings are small. In genera...

متن کامل

Applications of Confocal Laser Scanning Microscopy in Dentistry. Study of the changes of the post-extraction sites

The Confocal Laser Scanning Microscope (CLSM) is an optical microscope that includes a laser light as a light source and an electronic system which helps on image processing. It obtains high-resolution and extremely thin optical image sections, removing the interference caused by the light arriving from the different optical fields across the thickness of the sample, and focusing on a single pl...

متن کامل

Comparison of 3D microscopy methods by imaging a well characterized test object

We used a 10-μm-diameter fluorescent bead as a test object for 3D microscopy, and independently determined its structure by examining 1-μm-thick physical sections of the bead. Images of the full bead on different 3D microscopes revealed a number of aberrations and distortions. Images also showed evidence for absorption and/or scattering on all confocal and wide-field microscopes tested, but not...

متن کامل

Blind Deconvolution in 3d Biological Microscopy

Confocal microscopy o ers several advantages over conventional optical microscopy with its small depth-ofeld, its reduction of out-of-focus blur, and its full three-dimensional (3D) image scanning ability. For biomedical applications, it can also acquire images of living cells, usually labeled with one or more uorescent probes. The confocal laser scanning microscope (CLSM) is an optical uoresce...

متن کامل

Confocal Microscopy in Cell Physiology and Bioengineering

The fluorescent dyes or cellular autofluorescence can be used in studies of cell structure and in physiological measurements. The confocal microscope collects the information from a welldefined optical section; thus, out of focus fluorescence is eliminated, which results in an increase in contrast, clarity and detection of optical objects. Moreover, stacks of optical sections taken at successiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of electronic imaging

دوره 16 3  شماره 

صفحات  -

تاریخ انتشار 2007