The Measurement of Co-efficient of Friction between Cast Co-cr Alloy and Guiding Plane Materials - a Pilot Study
نویسنده
چکیده
The purpose of this pilot investigation was to measure the co-efficient of friction of a cast cobaltchromium alloy specimen and three materials commonly found on the guiding surfaces of the teeth. The static .co-efficients of friction between dental cobalt-chromium alloy (before and after electropolishing) and tooth enamel, composite resin, and dental amalgam alloy were measured using an inclined plane method at 20 ± 1° C. The mean measured co-efficients of friction between cobalt — chromium alloy and dental composite resin, dental enamel, and dental amalgam alloy together with their standard deviations were 0.68 ± 0.03, 0.45 ± 0.03 and 0.58 ± 0.04 respectively. Electro-polishing had no effect. This limited experiment suggested that dental composite resin should be preferred to dental amalgam for the restoration of buccal or guiding plane surfaces of abutment teeth to enhance the retention of cobalt-chromium partial denture. However, other properties of these materials may need to be taken into account. On the basis of the results of this pilot study, further research is required to investigate the difference in values of the coefficient of friction between various types of composite resin and amalgam alloys commercially available. Index Words: Partial Denture Retention, Frictional Resistance, Abutment restoration.
منابع مشابه
تولید، مشخصه یابی و ارزیابی خواص مکانیکی نانوکامپوزیت آلیاژ پایه کبالت با تقویت کننده نانوپودر فورستریت
Short life of current total hip replacement metallic implants is generally dependent on the aseptic loosening of the implant, which occurs due to mismatch of elastic modulus between bone and metallic implant materials. Decreasing in elasticmodulus of implant could be successful. Forsterite is biocompatible and bioactive ceramic which has suitable mechanical properties. In presented research the...
متن کاملComparative study between laser sintering and casting for retention of resin composite veneers to cobalt-chromium alloy.
The purpose of this study was to evaluate and compare the bond strengths between resin composite veneer and laser-sintered cobalt-chromium (Co-Cr) alloy with and without retention devices (Laser-R and Laser-N respectively). Cast Co-Cr alloy with and without retention devices (Cast-R and Cast-N respectively) were also prepared for fabrication technique comparison. Disk-shaped Co-Cr alloy specime...
متن کاملEffect of Mold Preheating on the Microstructure of the Investment Cast Astm F-75 Implant Alloy
The ASTM F-75 (Co-28%Cr-6%Mo) is widely used as a biocompatible alloy in medicinefor manufacturing implants. In this study, effect of mold preheating on the as-cast microstructure of thealloy was investigated using the solid investment casting process. Several mold preheating temperaturesof 550, 700, 850 and 1000 °C were selected at the same melt superheat. The samples were characterizedby opti...
متن کاملJoint properties of cast Fe-Pt magnetic alloy laser-welded to Co-Cr alloy.
This study investigated the joint properties of Fe-Pt alloy laser-welded to Co-Cr alloy. Cast plates (0.5 x 3.0 x 10 mm) were prepared with Fe-Pt and Co-Cr alloys. Fe-Pt plates were butted against Co-Cr plates and laser-welded using Nd:YAG laser. Control and homogeneously welded specimens were also prepared. Laser welding was performed with and without argon shielding. Tensile testing was condu...
متن کاملEffect of TiO2 nano-particles on corrosion behavior of Co-Cr alloy coatings in simulated body fluid
Co-Cr and Co-Cr/nano-TiO2 coatings were electrodeposited from Cr(III) based baths. The effect of TiO2 nano-particles incorporation on the morphology, structure, crystallite size, and preferred orientation was studied. Corrosion behavior of the composite coating was also investigated by means of polarization and electrochemical impedance spectroscopy techniques in Hanks’ si...
متن کامل