SU-E-T-163: Reproducibility in the Field of Patient-Specific IMRT QA.

نویسندگان

  • E McKenzie
  • P Balter
  • J Jones
  • D Followill
  • F Stingo
  • S Kry
چکیده

PURPOSE To analyze the reproducibility of patient specific IMRT QA results across five different clinical devices and one in-house detector by quantifying variations in the QA results from delivery-to-delivery (without re-setup, "redelivery") and variations when set-up is repeated ("re-setup"). METHODS Six patient plans were selected from among four treatment sites. Six methods of IMRT QA were chosen: film and cc04 ion chamber in a body phantom, diode array with all fields AP, as well as with fields delivered rotationally (in a MapPhan phantom), and an in-house designed solid water phantom with an insert containing 5 ion chambers that can rotate to eight positions. Each of the six plans was delivered three times. The system was then re-setup and redelivered. This last step was repeated, giving three redelivered plans, and three plans that were delivered under independent set ups. Reproducibility was quantified by the coefficients of variation (CV) of the re-deliveries and the re-setup deliveries. RESULTS Of all detectors investigated, film has the highest CV, with an average CV of 1.56% for re-deliveries, and 2.46% for re-setup. For the re-setup and re-delivery, the lowest average CV's are the AP diode array with 0.25%, and the ion chamber with 0.13%, respectively. Additionally the standard deviation in dose across the ion chambers calculated by the TPS was compared to the standard deviation of the re-setup measurements for the in-house phantom, giving a weak correlation. CONCLUSION Different IMRT QA devices exhibit different reproducibility; however all CV's were lower than 5%, indicating good consistency in measurement. Film's dependence on the processor and choice of normalization point are possible reasons why this dosimetry system had a higher CV. This information will help quantify the confidence of IMRT QA performed in the clinic and provide valuable information on the reproducibility of various IMRT QA devices. This work was supported by Public Health Service grants CA010953, CA081647, and CA21661 awarded by the National Cancer Institute, United States Department of Health and Human Services.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reproducibility in patient‐specific IMRT QA

The purpose of this study was to determine the reproducibility of patient-specific, intensity-modulated radiation therapy (IMRT) quality assurance (QA) results in a clinical setting. Six clinical patient plans were delivered to a variety of devices and analyses, including 1) radiographic film; 2) ion chamber; 3) 2D diode array delivered and analyzed in three different configurations (AP deliver...

متن کامل

Comparison between two different methods used for IMRT plans QA of Prostate cancer

Introduction: The aim of this study is evaluation of two Quality Assurance methods in sliding window IMRT technique and Determination of gamma index in both methods   Materials and Methods: In this study two tools named" Delta4" phantom and " Epiqa" software has been used to perform QA on the treatment plan before the actual treatment by Varian linear acceler...

متن کامل

SU-E-T-164: Clinical Implementation of ASi EPID Panels for QA of IMRT/VMAT Plans.

PURPOSE To investigate various issues for clinical implementation of aSi EPID panels for IMRT/VMAT QA. METHODS Six linacs are used in our clinic for EPID-based plan QA; two Varian Truebeams, two Varian 2100 series, two Elekta Infiniti series. Multiple corrections must be accounted for in the calibration of each panel for dosimetric use. Varian aSi panels are calibrated with standard dark fiel...

متن کامل

3D Analysis of Intensity-Modulated Radiation Therapy Quality Assurance Measurement using a 2D Diode Array

Intensity-modulated radiation therapy (IMRT) quality assurance (QA) is often performed using a 2D device and compares measured and computed fluence maps to determine if a field passes or fails certain dose and position criteria. The effects of a measured deviation to the 3D patient spatial dosimetry and dose volume histogram (DVH) are largely unknown because they cannot be analyzed using commer...

متن کامل

Statistical process control analysis for patient-specific IMRT and VMAT QA

This work applied statistical process control to establish the control limits of the % gamma pass of patient-specific intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) quality assurance (QA), and to evaluate the efficiency of the QA process by using the process capability index (Cpml). A total of 278 IMRT QA plans in nasopharyngeal carcinoma were measured with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 40 6Part13  شماره 

صفحات  -

تاریخ انتشار 2013