Multibore sample cell increases EPR sensitivity for aqueous samples.
نویسندگان
چکیده
We have performed calculations, verified by experiment, to explain why the sensitivity of biological EPR can be dramatically increased by dividing the aqueous sample into separate compartments. In biological EPR, the major factor affecting sensitivity is the number of spins in the sample. For an aqueous sample at ambient temperature, this is limited by the requirement for a small volume, due to strong non-resonant absorption of microwaves by water. However, recent empirical studies have shown that this volume limitation can be greatly relieved by dividing the aqueous sample into separate volumes, which allows much more aqueous sample to be loaded into a resonant cavity without significant degradation of the cavity quality factor. Calculations, based on the Bruggeman mixing rule, show quantitatively that the composite aqueous sample has a permittivity much less than that of bulk water, depending on the aqueous volume fraction f. Analysis for X-band EPR spectroscopy shows that the optimal volume fraction of an aqueous composite sample, producing maximum sensitivity, is f=0.15, increasing the sensitivity by a factor of 8.7, compared with an aqueous sample in a single tube.
منابع مشابه
Aqueous sample in an EPR cavity: sensitivity considerations.
The radial mode matching (RMM) method has been used to calculate accurately the microwave field distribution of the TE(011) mode in a spherical EPR cavity containing a linear aqueous sample, in order to understand in detail the factors affecting sensitivity in EPR measurements at X band. Specific details of the experiment were included in the calculations, such as the cavity geometry, the prese...
متن کاملToward increased concentration sensitivity for continuous wave EPR investigations of spin-labeled biological macromolecules at high fields.
High-field, high-frequency electron paramagnetic resonance (EPR) spectroscopy at W-(∼94 GHz) and D-band (∼140 GHz) is important for investigating the conformational dynamics of flexible biological macromolecules because this frequency range has increased spectral sensitivity to nitroxide motion over the 100 ps to 2 ns regime. However, low concentration sensitivity remains a roadblock for studyi...
متن کاملEnhanced EPR sensitivity from a ferroelectric cavity insert.
We report the development of a simple ferroelectric cavity insert that increases the electron paramagnetic resonance (EPR) sensitivity by an order of magnitude when a sample is placed within it. The insert is a hollow cylinder (length 4.8 mm, outside diameter 1.7 mm, inside diameter 0.6 mm) made from a single crystal of KTaO(3), which has a dielectric constant of 230 at X-band (9.5 GHz). Its ou...
متن کاملElectrochemical electron paramagnetic resonance utilizing loop gap resonators and micro-electrochemical cells.
A miniaturised electrochemical cell design for Electron Paramagnetic Resonance (EPR) studies is reported. The cell incorporates a Loop Gap Resonator (LGR) for EPR investigation of electrochemically generated radicals in aqueous (and other large dielectric loss) samples and achieves accurate potential control for electrochemistry by using micro-wires as working electrodes. The electrochemical be...
متن کاملHigh-field dynamic nuclear polarization in aqueous solutions.
Unexpected high DNP enhancements of more than 10 have been achieved in liquid water samples at room temperature and magnetic fields of 9.2 T (corresponding to 400 MHz (1)H NMR frequency and 260 GHz EPR frequency). The liquid samples were polarized in situ using a double-resonance structure, which allows simultaneous excitation of NMR and EPR transitions and achieves significant DNP enhancements...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance
دوره 178 2 شماره
صفحات -
تاریخ انتشار 2006