THESIS DEFENSE DEBASHISH PAL Biomedical Engineering Department Washington University in St. Louis IMAGE RECONSTRUCTION FOR A HIGH RESOLUTION PET-INSERT SCANNER
ثبت نشده
چکیده
Positron emission tomography (PET) is widely used in clinical diagnosis as it provides metabolic and functional information about an organ of interest or the whole body. We are developing novel insert devices for existing PET scanners to achieve higher resolution in selected regions of interest such as the head, neck, breast, or abdomen. In this work, the insert is a ring of high-resolution detectors placed concentrically inside a scanner. Adding the insert inside the scanner leads to three different types of coincidence data: insert-insert, insert-scanner, and scannerscanner. The insert-scanner coincidences have an unconventional geometry and hence a novel image reconstruction method is developed. The two-dimensional model of the system matrix is developed for a full-ring insert and is based on the intersection of a fan with a pixel and the same approach is extended in three-dimensions. This model is further modified to better describe a new geometry for a half-ring PET-insert system and improvement in the accuracy of the model is demonstrated using a point source simulation study. A filtered back-projection (FBP) algorithm is developed in two-dimensions based on the novel idea of using a fanbeam geometry for the coincidences. This FBP algorithm yields images with significantly reduced artifacts compared to traditional FBP reconstruction on the insert-scanner data using parallel-beam geometry. A penalized maximum likelihood expectation-maximization (PML-EM) algorithm is developed to jointly estimate the activity distribution from all three datasets. The PML-EM algorithm is demonstrated to have a better resolution-noise tradeoff than the FBP algorithm. Factors such as attenuation from the insert, crystal detection efficiency are not modeled in the system matrix computation. Instead, they are included in a component-based normalization correction. Corrections for attenuation from the body and accidental coincidences are also discussed. Phantoms and animals are imaged in a fully functional prototype insert system attached to a microPET F220 (Siemens Inc., Knoxville) scanner to validate the reconstruction algorithm. The resolution of the images reconstructed using all three types of coincidence data are demonstrated to have improved resolution compared to images reconstructed using coincidence data of type SS, which is close to the resolution of the original microPET F220.
منابع مشابه
Design and performance evaluation of spheroid geometry for brain PET scanner using Monte Carlo modeling
Introduction: There has been a curiosity about the spheroid geometry for PET scanners developments since several years ago, therefore in this study, we are aiming to evaluate the performance of this geometry and compare its performance with cylindrical geometry using Monte Carlo simulation. Methods: We simulated a spheroid geometry with a radius of 199 mm...
متن کاملPET/MR imaging of hypoxic atherosclerosis using 64Cu-ATSM in a rabbit model
ATSM in a rabbit model Xingyu Nie1, 2, Richard Laforest1, Andrew Elvington3, Gwendalyn J. Randolph3, Jie Zheng1, Tom Voller1, Dana R. Abendschein3,4, Suzanne E. Lapi1, 2, 3, Pamela K. Woodard1, 2, 5 Affiliations 1. Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, USA 2. Department of Biomedical Engineering, Washington University in St. Louis, MO, USA...
متن کاملMicro insert: a prototype full-ring PET device for improving the image resolution of a small-animal PET scanner.
UNLABELLED A full-ring PET insert device should be able to enhance the image resolution of existing small-animal PET scanners. METHODS The device consists of 18 high-resolution PET detectors in a cylindric enclosure. Each detector contains a cerium-doped lutetium oxyorthosilicate array (12 x 12 crystals, 0.72 x 1.51 x 3.75 mm each) coupled to a position-sensitive photomultiplier tube via an o...
متن کاملPerformance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE
Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...
متن کاملAutomated Archeological Survey of Ancient Irrigation Canals Abstract of the Thesis Automated Archaeological Survey of Ancient Irrigation Canals
In Ancient Southern Mesopotamia (now Iraq), rainfall was never high enough to sustain agriculture, so for thousands of years people used a system of canals to irrigate their fields. These canals, built up over generations, have long formed the basis of settlement patterns and state relations in the region, making their location and mapping of key interest to archaeologists. However, since 1991,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2007