A rapid technique for mapping of T(2) relaxation times is presented. The method is based on the conventional single-echo spin echo approach but uses a much shorter pulse repetition time to accelerate data acquisition. The premise of the new method is the use of a constant difference between the echo time and pulse repetition time, which removes the conventional and restrictive requirement of pulse repetition time >> T(1). Theoretical and simulation investigations were performed to evaluate the criteria for accurate T(2) measurements. Measured T(2)s were shown to be within 1% error as long as the key criterion of pulse repetition time/T(2) > or =3 is met. Strictly, a second condition of echo time/T(1) << 1 is also required. However, violations of this condition were found to have minimal impact in most clinical scenarios. Validation was conducted in phantoms and in vivo T(2) mapping of healthy cartilage and brain. The proposed method offers all the advantages of single-echo spin echo imaging (e.g., immunity to stimulated echo effects, robustness to static field inhomogeneity, flexibility in the number and choice of echo times) in a considerably reduced amount of time and is readily implemented on any clinical scanner.
منابع مشابه
Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملRapid and accurate T2 mapping from multi-spin-echo data using Bloch-simulation-based reconstruction.
PURPOSE Quantitative T2 -relaxation-based contrast has the potential to provide valuable clinical information. Practical T2 -mapping, however, is impaired either by prohibitively long acquisition times or by contamination of fast multiecho protocols by stimulated and indirect echoes. This work presents a novel postprocessing approach aiming to overcome the common penalties associated with multi...
متن کاملRapid T2* mapping using interleaved echo planar imaging.
Magnetic resonance imaging methods that are sensitive to T2* are widely used in the study of blood oxygenation changes, most notably in functional studies of the brain. In these studies the signal intensity change in T2*-weighted imaging is related to the coupling of cerebral blood flow and metabolism. Rapid measurement of T2* itself would offer a valuable method to quantify blood oxygenation c...
متن کاملComparison of Quantitative T2 Mapping Techniques for Articular Cartilage
Introduction: T2 relaxation time mapping of free water content and mobility in articular cartilage provides an indirect assessment of collagen content and orientation [1]. Biochemical changes are characteristic of the early stages of osteoarthritis (OA), and T2 mapping is increasingly used in both clinical and research settings. New MR pulse sequences, including 3D approaches, provide more adva...
متن کاملModel-based nonlinear inverse reconstruction for T2 mapping using highly undersampled spin-echo MRI.
PURPOSE To develop a model-based reconstruction technique for T2 mapping based on multi-echo spin-echo MRI sequences with highly undersampled Cartesian data encoding. MATERIALS AND METHODS The proposed technique relies on a nonlinear inverse reconstruction algorithm which directly estimates a T2 and spin-density map from a train of undersampled spin echoes. The method is applicable to acquisi...