Cemented hip revision surgery in severe acetabular defects using a semirigid acetabular reinforcement ring--a 5- to 25-year follow-up study.
نویسندگان
چکیده
Between 1978 and 1998, a total of 38 consecutive acetabular component revisions were performed in 38 patients. Average age was 67 years, and 87% of patients had severe uncontained segmental acetabular defects of more than 50%. We describe the operative technique of acetabular component revisions performed with bone grafting and a steel, semirigid acetabular reinforcement ring (Eichler), and long-term results are presented. After an average of 11.2 years follow-up, 1 cup was revised after 0.8 years for mechanical loosening, but the ring remained stably fixed. Remodeling (partial) of autografts occurred in all cases. The average HHS was 72.5. The Eichler reinforcement ring is a viable option for segmental acetabular defects in revision hip surgery, allows for restoration of pelvic bone, and makes future revisions feasible.
منابع مشابه
Hip Arthroplasty and its Revision in a Child: Case Report and Literature Review
Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...
متن کاملAcetabular revision with impacted morsellised cancellous bone grafting and a cemented acetabular component: a 20- to 25-year follow-up.
We present an update of the clinical and radiological results of 62 consecutive acetabular revisions using impacted morsellised cancellous bone grafts and a cemented acetabular component in 58 patients, at a mean follow-up of 22.2 years (20 to 25). The Kaplan-Meier survivorship for the acetabular component with revision for any reason as the endpoint was 75% at 20 years (95% confidence interval...
متن کاملExcellent long-term results of the Müller acetabular reinforcement ring in primary cup revision
Background and purpose - The original Müller acetabular reinforcement ring (ARR) was developed to be used for acetabular revisions with small cavitary and/or segmental defects or poor acetabular bone quality. Long-term data for this device are scarce. We therefore investigated long-term survival and radiographic outcome for revision total hip arthroplasty using the ARR. Patients and methods - B...
متن کاملRevision total hip arthroplasty using a Kerboull-type acetabular reinforcement device with bone allograft: minimum 4.5-year follow-up results and mechanical analysis.
We retrospectively reviewed 40 hips in 36 patients who had undergone acetabular reconstruction using a titanium Kerboull-type acetabular reinforcement device with bone allografts between May 2001 and April 2006. Impacted bone allografts were used for the management of American Academy of Orthopaedic Surgeons Type II defects in 17 hips, and bulk bone allografts together with impacted allografts ...
متن کاملThe use of morselized allografts without impaction and cemented cage support in acetabular revision surgery: a 4- to 9-year follow-up
BACKGROUND Acetabular revision arthroplasty with major bone loss is one of the most difficult operations in orthopedic surgery. The goal of the study was to evaluate midterm clinical results of the use of morselized allografts with cemented cage support in revision total hip replacement. METHODS We identified 28 patients (29 hips) at an average follow-up of 73 months. Harris Hip Scores (HHS) ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of arthroplasty
دوره 24 2 شماره
صفحات -
تاریخ انتشار 2009