A rapid, simple measurement of human albumin in whole blood using a fluorescence immunoassay (I).

نویسندگان

  • Sunga Choi
  • Eui Yul Choi
  • Dong Joon Kim
  • Jae Hoon Kim
  • Tai Sun Kim
  • Sang Wook Oh
چکیده

BACKGROUND Human serum albumin (HSA) is the most abundant plasma protein and plays key a role in metabolism. The variation in albumin concentration provides valuable information related to metabolic diseases and diagnostic application. METHODS We constructed two assay systems to quantify the albumin concentration. The immunoassay used a fluorescence (FL) dye to detect albumin in samples and employed the conventional chromatography as a separation system. The assay system consists of an anti-HSA-mAb or an HSA immobilized test strip in a disposable cartridge, a fluorescence-labeled detector buffer and a laser-fluorescence scanner. We mixed the sample with detector, loaded it onto a cartridge, incubated it for 10 min and measured the concentration of albumin in a laser-fluorescence scanner. We examined the comparability of assay with an automated BCG dye binding method using a Hitachi 747 biochemical analyzer. RESULTS The correlation of coefficient between AT/AC as converted from the relative fluorescence units (RFU) and albumin concentration displayed reasonable reliability in both the competition and the inhibition assay systems (r = 0.998). Using the Bland-Altman difference plot analysis, we observed an acceptable agreement between two methods, the fluorescence immunochromatography assay (FL-ICA) and the automated BCG dye-binding method of a Hitachi biochemical analyzer, over the clinical relevant range of HSA concentrations. The coefficient of variation (CV) of within- and between-run variation in the immunoassay system was < 8% and the recovery fell within 5% in each control sample. In addition to its reliable analytical performance, the assay with whole blood can be completed in 12 min using a one-step operation without any pretreatment. CONCLUSION The developed immunoassay system using fluorescence dye and lateral-flow chromatography is a simple, fast and reliable method for quantifying the albumin concentration in whole blood.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Highly Sensitive FRET-Based Fluorescence Immunoassay for Detecting of Aflatoxin B1 Using Magnetic/Silica Core-Shell as a Signal Intensifier

Background: Recently, some new nanobiosensors using different nanoparticles or microarray systems for detection of mycotoxins have been designed . However, rapid, sensitive and early detection of aflatoxicosis would be very helpful to distinguish high-risk persons. Objectives: We report a highly sensitive competitive immunoassay using magnetic/silica core shell as a signal intensifier for the d...

متن کامل

Rapid and sensitive detection of troponin I in human whole blood samples by using silver nanoparticle films and microwave heating.

BACKGROUND Cardiovascular diseases are among the leading causes of mortality in developed countries. It is widely recognized that troponin I (TnI) can be used for the assessment of a myocardial infarction. METHODS We investigated the use of the microwave-accelerated and metal-enhanced fluorescence (MA-MEF), a technique based on the combined use of low-power microwave heating, silver nanoparti...

متن کامل

DEVELOPMENT OF A RAPID AND SENSITIVE RADIOIMMUNOASSAY FOR MEASUREMENT OF AFLATOXIN B 1 IN BIOLOGICAL SAMPLES

Aflatoxin B I (AFB) isa well known hepatocarcinogen in several animal species and probably a causative agent in human hepatocellular carcinoma. Humans are exposed to AFB by ingesting contaminated food. Aflatoxin contamination encountered in human foods is usually at low levels which is difficult to measure by chromatographic methods. Therefore in the present study we have developed an immun...

متن کامل

Quantification of Human Chorionic Gonadotropin by Bovine Serum Albumin Nanoparticles

Background and Aims: Some nanoparticles can be used in immunoassays to increase sensitivity. This study aimed to evaluate a novel nano-immunoassay based on bovine serum albumin nanoparticles (BSA NPs). Materials and methods: At first, the nanostructure was synthesized, and then applied as a tag in the nano-immunoassay. Then the concentration of &beta;-subunit of human chorionic gonadotropin ...

متن کامل

Quantitative, wide-range, 5-minute point-of-care immunoassay for total human chorionic gonadotropin in whole blood.

BACKGROUND Human chorionic gonadotropin (hCG) is among the most common analytes available for point-of-care immunotesting, with most assays currently based on simple manual assay devices. However, as the importance of good analytical performance of rapid assays is increasingly emphasized, more sophisticated immunoassay techniques are needed to meet the future challenges of rapid yet quantitativ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinica chimica acta; international journal of clinical chemistry

دوره 339 1-2  شماره 

صفحات  -

تاریخ انتشار 2004