Assessment of individual renal function in children using 99mTc-DTPA.

نویسندگان

  • G Kainer
  • B McIlveen
  • R Höschl
  • A R Rosenberg
چکیده

Differential renal function assessment using 99mTc-DTPA was carried out in 12 children aged between 3 weeks and 11 years who had undergone surgical procedures which allowed separate access to the urine output from each kidney. The results correlated well with those obtained by measuring individual kidney creatinine clearances. The best result was obtained using the technique of deconvolution analysis (r = 0.98; P less than 0.001). We conclude that the method is accurate and recommend its use in the management and follow-up of patients with asymmetric renal disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the individual renal function in chronic unilateral renal obstruction using functional CT as compared to 99mTc-DTPA renal scan

Introduction: The selection of   optimal treatment of obstructive nephrouropathy requires information about the functional status of each kidney. Nuclear renal scanning objectively measure differential renal function, multiple studies have demonstrated the role of assessment of renal perfusion and GFR with triphasic CT. The aim of this study is to assess the role of CT based on renal parenchyma...

متن کامل

Effect of Saffron (Crocus Sativus) Administration on Kidney Function in Normal Cats as Determined by Use of 99mTc-DTPA Renal Scintigraphy

Objective- To evaluate and compare kidney function with and without saffron administration and consider the diuretic and nephroprotective effects of aqueous extract of this substance in normal cats. Design- Descriptive study Animals- 6 female healthy cats (age: 2 to 4 years, average weight: 4 kg) - no clinical sign of renal disorders and prior to presentation Procedures- The scintigraphy of r...

متن کامل

Evaluation of 58 cases of 99mTc-DTPA renal transplantation scans [Persian]

Nuclear medicine methods have important role in the evaluation of transplanted kidney. In this study 58 99mTc-DTPA scans were performed in 38 patients. This method has 90% sensitivity and 96% specificity. In the cases of normal transplanted kidneys, function correlation between doppler sonography and scanning was more than dysfunctioning kidneys.

متن کامل

Comparison of relative renal function measured with either 99mTc-DTPA or 99mTc-EC dynamic scintigraphies with that measured with 99mTc-DMSA static scintigraphy.

OBJECTIVE The aim of this study was to compare the renal function measured with either 99mTc-DTPA or 99mTc-EC dynamic scintigraphies with that measured using 99mTc-DMSA static scintigraphy. METHODS the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with 99mTc-DTPA (55 studies) or with 99mTc-EC (56 studies) were compared with the relative functi...

متن کامل

Estimating the Absorbed Dose of Organs in Pediatric Imaging of 99mTc-DTPA Radiopharmaceutical using MIRDOSE Software

Introduction: In this study, organ radiation doses were calculated for the renal agent 99mTc-DTPA in children. Bio-kinetic energy of 99mTc-DTPA was evaluated by scintigraphy and estimates for absorbed radiation dose were provided using standard medical internal radiation dosimetry (MIRD) techniques.Material and Methods: In this applied research, fourteen children patients (6 males and 8 females...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood

دوره 54 12  شماره 

صفحات  -

تاریخ انتشار 1979