Repeatability of rest and hyperemic myocardial blood flow measurements with 82Rb dynamic PET.

نویسندگان

  • Osamu Manabe
  • Keiichiro Yoshinaga
  • Chietsugu Katoh
  • Masanao Naya
  • Robert A deKemp
  • Nagara Tamaki
چکیده

UNLABELLED The repeatability of rest and hyperemic myocardial blood flow (MBF) measurements using 82Rb PET has not been evaluated. The aim of this study was to investigate the short-term repeatability of such measurements. METHODS Fifteen healthy volunteers underwent rest and pharmacologic stress 82Rb PET, repeated 60 min apart. RESULTS There was no significant difference in repeated rest MBF (0.77+/-0.25 vs. 0.82+/-0.25 mL/min/g, P=0.31; mean difference, 6.18%+/-12.22%) or repeated hyperemic MBF (3.35+/-1.37 vs. 3.39+/-1.37 mL/min/g, P=0.81; mean difference, 1.17%+/-13.64%). The repeatability coefficients were 0.19 mL/min/g for rest MBF and 0.92 mL/min/g for hyperemia. CONCLUSION MBF using 82Rb is highly reproducible using a same-day short-term repeatability protocol. Serial MBF measurements with 82Rb PET should have the ability to quantify the acute effects of therapeutic interventions on MBF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repeatability of regional myocardial blood flow calculation in 82Rb PET imaging

BACKGROUND We evaluated the repeatability of the calculation of myocardial blood flow (MBF) at rest and pharmacological stress, and calculated the coronary flow reserve (CFR) utilizing 82Rb PET imaging. The aim of the research was to prove high repeatability for global MBF and CFR values and good repeatability for regional MBF and CFR values. The results will have significant impact on cardiac ...

متن کامل

Optimally Repeatable Kinetic Model Variant for Myocardial Blood Flow Measurements with 82Rb PET

Purpose. Myocardial blood flow (MBF) quantification with 82Rb positron emission tomography (PET) is gaining clinical adoption, but improvements in precision are desired. This study aims to identify analysis variants producing the most repeatable MBF measures. Methods. 12 volunteers underwent same-day test-retest rest and dipyridamole stress imaging with dynamic 82Rb PET, from which MBF was quan...

متن کامل

Noninvasive quantification of regional myocardial perfusion with rubidium-82 and positron emission tomography. Exploration of a mathematical model.

Positron emission tomography (PET) centers without cyclotrons use generator-produced rubidium-82 (82Rb) for assessment of myocardial perfusion. The aim of the present study was to determine whether myocardial blood flow could be assessed quantitatively with 82Rb and PET. Because the myocardial extraction fraction of 82Rb varies inversely and nonlinearly with flow and cannot be measured convenie...

متن کامل

Noninvasive Quantification of Regional Myocardial Perfusion With Rubidium-82 and Positron Emission Tomography

Positron emission tomography (PET) centers without cyclotrons use generator-produced rubidium-82 (82Rb) for assessment of myocardial perfusion. The aim of the present study was to determine whether myocardial blood flow could be assessed quantitatively with 82Rb and PET. Because the myocardial extraction fraction of 82Rb varies inversely and nonlinearly with flow and cannot be measured convenie...

متن کامل

Quantification of myocardial perfusion in human subjects using 82Rb and wavelet-based noise reduction.

UNLABELLED Quantification of myocardial perfusion with 82Rb has been difficult to achieve because of the low signal-to-noise ratio of the dynamic data curves. This study evaluated the accuracy of flow estimates after the application of a novel multidimensional wavelet-based noise-reduction protocol. METHODS Myocardial perfusion was estimated using 82Rb and a two-compartment model from dynamic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 50 1  شماره 

صفحات  -

تاریخ انتشار 2009