PURPOSE Design and validate an efficient dual-slot coaxial microwave ablation antenna that produces an approximately spherical heating pattern to match the shape of most abdominal and pulmonary tumor targets. METHODS A dual-slot antenna geometry was utilized for this study. Permutations of the antenna geometry using proximal and distal slot widths from 1 to 10 mm separated by 1-20 mm were analyzed using finite-element electromagnetic simulations. From this series, the most optimal antenna geometry was selected using a two-term sigmoidal objective function to minimize antenna reflection coefficient and maximize the diameter-to-length aspect ratio of heat generation. Sensitivities to variations in tissue properties and insertion depth were also evaluated in numerical models. The most optimal dual-slot geometry of the parametric analysis was then fabricated from semirigid coaxial cable. Antenna reflection coefficients at various insertion depths were recorded in ex vivo bovine livers and compared to numerical results. Ablation zones were then created by applying 50 W for 2-10 min in simulations and ex vivo livers. Mean zone diameter, length, aspect ratio, and reflection coefficients before and after heating were then compared to a conventional monopole antenna using ANOVA with post-hoc t-tests. Statistical significance was indicated for P <0.05. RESULTS Antenna performance was highly sensitive to dual-slot geometry. The best-performing designs utilized a proximal slot width of 1 mm, distal slot width of 4 mm +/- 1 mm and separation of 8 mm +/- 1 mm. These designs were characterized by an active choking mechanism that focused heating to the distal tip of the antenna. A dual-band resonance was observed in the most optimal design, with a minimum reflection coefficient of -20.9 dB at 2.45 and 1.25 GHz. Total operating bandwidth was greater than 1 GHz, but the desired heating pattern was achieved only near 2.45 GHz. As a result, antenna performance was robust to changes in insertion depth and variations in relative permittivity of the surrounding tissue medium. In both simulations and ex vivo liver, the dual-slot antenna created ablations greater in diameter than a coaxial monopole (35 mm +/- 2 mm versus 31 mm +/- 2 mm; P<0.05), while also shorter in length (49 mm +/- 2 mm versus 60 mm +/- 6 mm; P < 0.001) after 10 min. Similar results were obtained after 2 and 5 min as well. CONCLUSIONS Dual-slot antennas can produce more spherical ablation zones while retaining low reflection coefficients. These benefits are obtained without adding to the antenna diameter. Further evaluation for clinical microwave ablation appears warranted.
منابع مشابه
Heating Performances of Array Applicator for Interstitial Microwave Hyperthermia: Numerical Simulation and Clinical Trial
INTRODUCTION In recent years, various types of medical applications of microwaves have widely been investigated and reported [1]. In particular, minimally invasive microwave thermal therapies using thin applicators are of a great interest. They are interstitial microwave hyperthermia [2] and microwave coagulation therapy (MCT) [3] for medical treatment of cancer, cardiac catheter ablation for v...
متن کاملMulti Attribute Analysis of a Novel Compact UWB Antenna with Via-fed Elements for Dual Band Notch Function (RESEARCH NOTE)
A compact microstrip-fed antenna with dual notched bands is proposed. First, a simple basic configuration is presented for Ultra Wide Band (UWB) applications and then the dual band notched structure is extended from the UWB one. The basic structure of the UWB antenna consists of a simple square radiating patch and a ground plane with a wide square slot on back of the substrate. A semi-circle sh...
متن کاملDevelopment and Analysis of Coaxial Slot Antenna in Comparision with Coaxial Dipole Antenna for Interstitial Microwave Ablation
Hepatocellular carcinoma (HCC) is the most common malignant tumors to affect the liver. Microwave ablation is efficiently used for treatment of liver cancer. Although surgical resection remains the gold standard for treatment of liver cancer, but only 5-10% patients are the candidates for surgical resection due to numbers of limitations. Because most patients with HCC can not be treated with su...
متن کاملNovel Dual-band CPW-fed Monopole Slot Antenna for WLAN/WiMAX Applications
A novel dual-band design of a finite ground coplanar waveguide (CPW)-fed monopole antenna is presented for simultaneously satisfying wireless local area network (WLAN) and worldwide interoperability for Microwave Access (WiMAX) applications. The proposed antenna, comprising a rectangular planar patch element embedded with two L shaped slots and stair shape slot in the middle of the patch elemen...
متن کاملSun 53 Management of Localized Cancer Using Sleeved Dual Slot Antenna Microwave Ablation Tecnique
Cancer as global burden with increasing incidence is a second and among third cause of death in developed and developing economies respectively. Surgery, radiotherapy, chemotherapy, hormonal therapy and immunotherapy are the major management options. Thermal therapy is currently gaining attention as an alternative. Radiofrequency, laser, high intensity focused ultrasound, cryo and microwave abl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 38 7 شماره
صفحات -
تاریخ انتشار 2011