Supply Voltage Compensation of Hot Wire Flow Measurement Device
نویسندگان
چکیده
Supply voltage compensation is important to keep the accuracy for hot wire/hot film gas flow sensors. A compensation experiment device is established, the two steps curve fitting is presented to determine the functional relations among flow、sensor output and supply voltage, the coefficient of fitting polynomial is determined by Least Square method, thus eliminating the influence of supply voltage variations. After compensation, the error is reduced to 2%. The algorithm is stabilized, easily to be fullfilled in microcontroller unit.
منابع مشابه
An Adaptive Response Compensation Technique for the Constant-Current Hot-Wire Anemometer
An adaptive response compensation technique has been proposed to compensate for the response lag of the constant-current hot-wire anemometer (CCA) by taking advantage of digital signal processing technology. First, we have developed a simple response compensation scheme based on a precise theoretical expression for the frequency response of the CCA (Kaifuku et al. 2010, 2011), and verified its ...
متن کاملImproving Compensation Performance in Three- Phase Active Power Line Conditioners by DC-Voltage Control
This paper analyses the influence of the prescribed DC-link voltage on the filtering efficiency, in terms of current harmonic distortion after compensation, in a three-phase three-wire shunt active power line conditioner. The AC voltage controller as nonlinear load and two configurations of the coupling filter are taken into consideration. It is pointed out that, for each rms current to be comp...
متن کامل3-Phase 4-wire UPQC Topology with reduced DC-link Voltage rating for Power Quality Improvement using Fuzzy Controller
Unified power quality conditioner is one of the advanced forms of power conditioning device, which is a combination of back to back connected series APF and shunt active power filter (SAPF) connected to a common DC link voltage. This topology will facilitates this device to have a reduced dc-link voltage without reducing its compensation capability. This device is mainly used in improving the p...
متن کاملA Three Phase Four Wire Shunt Active Power Filter Control Algorithm under Unbalanced and Distorted Supply Voltage
In this paper a control algorithm is validated with simulation studies in MAT environment and experimental studies are performed in to validate the proposed control algorithm. The projected algorithm to compensate the nonlinear and loads in three phase four wire distribution system using shunt active power filter. In this algorithm a positive sequence extraction of the supply voltage and the th...
متن کاملThe Effectiveness of Dynamic Voltage Restorer with the Distribution Networks for Voltage Sag Compensation
This paper discusses the Dynamic voltage restorer (DVR) operation and control for Voltage sags compensation. DVR is a series connected power electronic based device that can quickly mitigate the voltage sags in the system and restore the load voltage to the pre-fault value. Voltage sag associated with faults in transmission and distribution systems, energizing of transformers, and starting of l...
متن کامل