Peak inspiratory flow rate and slope of the inhalation profiles in dry powder inhalers.

نویسندگان

  • M E Broeders
  • J Molema
  • N A Vermue
  • H T Folgering
چکیده

Aerosol delivery depends on device design and inhalation technique. In vitro device evaluations have shown that the emitted dose and fine particle mass of dry powder inhalers (DPIs) increase at high peak inspiratory flow rates (PIFR). Since the PIFR is mostly achieved after the release of the powder, slope of the pressure profile is also described as an important determinant. The aim of the present study was to assess whether the PIFR while using Diskus it and Turbuhaler it inhalers could be used to predict the slope of the inhalation pressure profile. In a group of 10 stable asthma patients and three groups (mild, moderate and severe) of 16 chronic obstructive pulmonary disease (COPD) patients, lung function was measured, and for each device, 18 inhalation profiles were recorded with the inhalation profile recorder during six sessions over 10 weeks. The values for the pressure slope and PIFR of both Diskus and Turbuhaler, were significantly correlated. The r-values were 0.865 and 0.882, respectively (p<0.01). Percentage explained variance was 74.8% for Diskus and 77.8% for Turbuhaler. Significant correlations were found between peak inspiratory flow rates and slopes. It has been shown for two different dry powder inhalers that peak inspiratory flow rate and slope correlate well in a wide range of patient groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimal inspiratory flow from dry powder inhalers according to a biphasic model of pressure vs. flow relationship.

Inhalation therapy using the dry powder inhaler (DPI) is now the first choice for obstructive pulmonary diseases. We previously measured relationships between inspiratory pressure (PI) and flow rate of almost all of the DPIs available in Japan, and described an importance of inspiratory efforts. In the present study, we further analyzed the data obtained in the previous study. Although there we...

متن کامل

Scintigraphic comparison of budesonide deposition from two dry powder inhalers.

Chlorofluorocarbons (CFCs), used in metered dose inhalers (MDIs), have been identified as being deleterious to the environment leading to a ban on their production. Dry powder inhalers (DPIs) are a widely used alternative to MDIs. One disadvantage of DPIs is that in vivo lung deposition can be influenced by the patient's inspiratory flow rate. The ASTA Medica multi-dose dry powder inhaler (AM-M...

متن کامل

Ventolin Diskus and Inspyril Turbuhaler: An In Vitro Comparison

Dose delivery (total emitted dose, or TED) from dry powder inhalers (DPIs), pulmonary deposition, and the biological effects depend on drug formulation and device and patient characteristics. The aim of this study was to measure, in vitro, the relationship between parameters of inhalation profiles recorded from patients, the TED and fine particle mass (FPM) of Diskus and Turbuhaler inhalers. In...

متن کامل

Assessment of inhalation flow patterns of soft mist inhaler co-prescribed with dry powder inhaler using inspiratory flow meter for multi inhalation devices

The patients' inhalation flow pattern is one of the significant determinants for clinical performance of inhalation therapy. However, the development of inhalation flow meters for various inhalation devices has been unable to keep up with the increasing number of newly launched inhalation devices. In the present study, we developed simple attachment orifices for the inhalation flow pattern moni...

متن کامل

Effect of Inhaler Design Variables on Paediatric Use of Dry Powder Inhalers

Age appropriateness is a major concern of pulmonary delivery devices, in particular of dry powder inhalers (DPIs), since their performance strongly depends on the inspiratory flow manoeuvre of the patient. Previous research on the use of DPIs by children focused mostly on specific DPIs or single inspiratory parameters. In this study, we investigated the requirements for a paediatric DPI more br...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 18 5  شماره 

صفحات  -

تاریخ انتشار 2001