Efficacy and safety of an irrigated-tip catheter for the ablation of accessory pathways resistant to conventional radiofrequency ablation.

نویسندگان

  • T Yamane
  • P Jaïs
  • D C Shah
  • M Hocini
  • J T Peng
  • I Deisenhofer
  • J Clémenty
  • M Haïssaguerre
چکیده

BACKGROUND Radiofrequency catheter ablation of accessory pathways (APs) is very effective in all but a minority of patients. We examined the usefulness and safety of irrigated-tip catheters in treating patients with APs resistant to conventional catheter ablation. METHODS AND RESULTS Among 314 APs in 301 consecutive patients, conventional ablation failed to eliminate AP conduction in 18 APs in 18 patients (5.7%), 6 of which were located in the left free wall, 5 in the middle/posterior-septal space, and 7 inside the coronary sinus (CS) or its tributaries. Irrigated-tip catheter ablation was subsequently performed with temperature control mode (target temperature, 50 degrees C), a moderate saline flow rate (17 mL/min), and a power limit of 50 W (outside CS) or 20 to 30 W (inside CS) at previously resistant sites. Seventeen of the 18 resistant APs (94%) were successfully ablated with a median of 3 applications using irrigated-tip catheters. A significant increase in power delivery was achieved (20.3+/-11.5 versus 36.5+/-8.2 W; P:<0.01) with irrigated-tip catheters, irrespective of the AP location, particularly inside the CS or its tributaries. No serious complications occurred. CONCLUSIONS Irrigated-tip catheter ablation is safe and effective in eliminating AP conduction resistant to conventional catheters, irrespective of the location.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiofrequency catheter ablation in the treatment of Wolff-Parkinson-White syndrome

Introduction: Tachyarrhythmias in Wolf Parkinson White (WPW) syndrome, can be a life threatening factor. Antiarrhythmic drug therapy in this syndrome, has not been completely acceptable. Efficacy, safety and economy of Radio Frequency Catheter Ablation (RFCA) in western studies, has made it as the treatment of choice. In the present study, efficacy of RFCA in the ablation of accessory pathway...

متن کامل

Successful irrigated-tip catheter ablation of atrial flutter resistant to conventional radiofrequency ablation.

BACKGROUND Catheter ablation of typical right atrial flutter is now widely performed. The best end point has been demonstrated to be bidirectional isthmus block. We investigated the use of irrigated-tip catheters in a small subset of patients who failed isthmus ablation with conventional radiofrequency (RF) ablation. METHODS AND RESULTS Of 170 patients referred for ablation of common atrial f...

متن کامل

Cryoablation with an 8-mm-Tip Catheter for Right-Sided Accessory Pathways in Children.

BACKGROUND Cryoablation is increasingly utilized in children because of its safety profile. Recently, larger catheter tips have been more widely used to improve long-term success rates. The aim of this study was to assess the safety and efficacy of 8-mm-tip catheters for cryoablation of right-sided accessory pathways (APs) in children. METHODS Electrophysiological procedures were performed us...

متن کامل

Prospective randomized comparison of irrigated-tip versus conventional-tip catheters for ablation of common flutter.

BACKGROUND Radiofrequency (RF) ablation of common flutter requires the creation of a complete ablation line to produce bidirectional conduction block in the cavotricuspid isthmus. An irrigated-tip ablation catheter has been shown to be effective in patients in whom conventional ablation has failed. This randomized study compares the efficacy and safety of this catheter with those of a conventio...

متن کامل

Remote-controlled catheter ablation of accessory pathways: results from the magnetic laboratory.

AIMS This study evaluates feasibility, safety, and efficacy of magnetic remote-controlled accessory pathway (AP) ablation. METHODS AND RESULTS The novel magnetic navigation system (MNS) (Niobe, Stereotaxis) creates a steerable magnetic field (0.08 T) controlling the distal magnetic tip of an ablation catheter. In conjunction with a catheter advancer system (Cardiodrive, Stereotaxis) remote ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 102 21  شماره 

صفحات  -

تاریخ انتشار 2000