Blood Urea Nitrogen Stability: A Feasibility Study for Home Hemodialysis Adequacy Testing Through Mail.

نویسندگان

  • Gay L Case
  • Lynn Pierce
  • Debbie Vigil
چکیده

Urea kinetic modeling measures the delivered dose of hemodialysis and is used to monitor dialysis adequacy. Obtaining samples for adequacy calculations is a challenge for home hemodialysis (HHD) patients. Ideally, the urea reduction ratio (URR) should be measured at a typical dialysis session; therefore, for HHD patients test specimens should be drawn at home and transferred to a clinical laboratory. Would blood urea nitrogen (BUN) remain stable if samples were mailed to the laboratory? To answer this question, BUN was measured in pre- and postdialysis samples from 20 patients over 8 days of laboratory storage. While BUN values varied among the patient population, neither pre- nor postdialysis values showed any significant variation during the 8-day storage time. These results suggest that BUN values are sufficiently stable for specimens to be drawn at home and mailed to a testing laboratory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-Flux and Low-Flux Membranes in Hemodialysis

Background: Inadequacy of dialysis is one of the main causes of death in hemodialysis patients. Some studies have suggested that highflux membrane improves removal of moderatemolecules while other studies no significant on them. Objectives: The aim of this study was to investigate the dialysis adequacy of low-flux versus high-flux membranes in Hemodialysis Patients. Patients and Methods: Forty ...

متن کامل

Quantitating Dialysis in the Home Hemodialysis Patient: A Simple and Practical Approach.

Home hemodialysis is the most cost-effective form of dialysis and is associated with the lowest mortality. Home hemodialysis patients are usually highly motivated, independent, and actively employed. Because of the minimal supervision they require and the fact that they are not in a controlled environment, it is easy to overlook the measurement of their dialysis adequacy. We studied 6 home hemo...

متن کامل

The Evaluation of Dietary Protein Intake by Calculation of Urea Generation Rate in Chronic Dialysis Patients in Kerman, 2002

Malnutrition is a common problem in chronic dialysis patients. There are several methods for nutritional assessment of hemodialysis patients, such as calculation of urea generation rate. As urea is produced from proteins catabolism and there is a linear correlation between urea generation and protein catabolic rate (PCR), PCR can be calculated by considering urea nitrogen appearence during the ...

متن کامل

Stability of biochemical analytes of end stage renal failure patients on renal replacement therapy for urea-kinetic modeling in the home dialysis setting

Renal dialysis patients have biochemical analysis performed monthly to determine the adequacy of dialysis. These are analysed by taking blood in a clotted gel tube preand post-dialysis sessions, immediately centrifuged and sent to the laboratory for analysis. Certain patients (like home dialysis patients) cannot have the samples immediately centrifuged, as they are taken in a home environment. ...

متن کامل

Inherent Errors in the Quantitation of Dialysis Delivery: Implications For CAPD and Daily Hemodialysis.

When compared to intermittent dialysis, the theoretical advantages of continuous dialysis may be less important than its practical disadvantage: the inability to accurately quantify dialysis. With intermittent dialysis the change in blood urea nitrogen over the course of the treatment allows the ratio of K (urea clearance) to V (volume of distribution of urea or total body water) to be determin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Home hemodialysis international. International Symposium on Home Hemodialysis

دوره 3 1  شماره 

صفحات  -

تاریخ انتشار 1999