Reliability and validity of the GymAware optical encoder to measure displacement data
نویسنده
چکیده
The purpose of this study was to determine the reliability and validity of the GymAware optical encoder (Kinetic, Canberra, ACT) to measure displacement data (distance, peak velocity, mean velocity and time). Three GymAware sensors were attached to a Calibration Rig (CalRIG), a novel piece of technology engineered specifically for accurate calibration of dynamometry equipment. The CalRIG was programmed to perform 4 identical sets of 14 repetitions, each repetition increasing in displacement by 0.1m and 0.2m/s. Validity of displacement measures by GymAware were evaluated by typical error estimate (TEE), intraand interreliability was assessed through typical error measurement (TEM). TEE values were very low at 0.00m for distance and 0.01m/s for mean and peak velocity variables. TEE was higher at up to 0.16s for time (repetition duration). TEM was 0.00m for distance, 0.010.02m/s for velocity and 0.01-0.02s for repetition duration variables when comparing both between sensors and between sets. In conclusion, the GymAware optical encoder accurately measured displacement of the CalRIG shaft, thereby indicating its validity as a linear position transducer employed to calculate other strength and power related variables of interest through differentiation of measured displacement data. GymAware was found to be highly reliable with little variation between sets or sensors, of great benefit to practitioners or coaches utilizing GymAware in assessment and monitoring of athletic performance over time. It is recommended that consumers use velocity as a performance indicator as the measurement of this variable showed only minor error. A Smith machine is also recommended during resistance exercises to control the direction of displacement and facilitate measurement.
منابع مشابه
Ultra-Fast All-Optical Symmetry 4×2 Encoder Based on Interface Effect in 2D Photonic Crystal
This paper deals with the design and simulation of all-optical 4×2 encoderusing the wave interference effect in photonic crystals. By producing 4 opticalwaveguides as input and two waveguides as output, the given structure was designed.The size of the designed structure is 133.9 μm2. The given all-optical encoder has acontrast ratio of 13.2 dB, the response time of 0.45 ...
متن کاملA New Proposal for 4-to-2 Optical Encoder Using Nonlinear Photonic Crystal Ring Resonators
In this paper, we proposed an all optical 4-to-2 encoder that has 4 input and 3 output ports. This device generates a 2 bit binary code based on which input port is active. We used nonlinear photonic crystal ring resonators along with optical power splitter for realizing the proposed encoder. In this device the switching rate and area are obtained about 333 GHz and 612µm2 respectively.
متن کاملAn Optical Measurement System to Measure Velocity and Provide Shock Wave Pressure Diagrams
This paper introduces an optical measurement system for shock wave characteristics. The system works by mountinga metal plate attached to spring mounts against the shock wavefront. This set is sealed and can plot the shock wave pressure diagram by measuring plate's displacement, radiation and changing the reflection of light during shock wave conflict, and converting these optical data to volta...
متن کاملIntegration of Deep Learning Algorithms and Bilateral Filters with the Purpose of Building Extraction from Mono Optical Aerial Imagery
The problem of extracting the building from mono optical aerial imagery with high spatial resolution is always considered as an important challenge to prepare the maps. The goal of the current research is to take advantage of the semantic segmentation of mono optical aerial imagery to extract the building which is realized based on the combination of deep convolutional neural networks (DCNN) an...
متن کاملReliability, validity, and factor structure of global measure of relationship satisfaction
Reproduction of scoring and interpretation of conceptual model underlying global measure of relationship satisfaction (GMREL) scale are prerequisites to the use of it in cross-cultural studies. This study was carried out to examine the factor structure and the psychometric properties of the Iranian version of GMREL. The participants of this study consisted of 299 patients (men=128 and women=171...
متن کامل