The ASKAP Roll Axis Preliminary study of its benefits to calibration and imaging
نویسندگان
چکیده
A standard test field containing numerous strong sources has been observed twice with the ASKAP BETA system, with the third axis of motion – the roll axis – disabled for the second run. These two data sets are subjected to identical calibration and imaging pipelines in order to gauge the e↵ects of the roll axis when observing with a Phased Array Feed. Present beam forming techniques only allow meaningful comparisons to be performed with the on axis ‘boresight’ beam. Observing with the roll axis tracking reduces the standard deviation of the close-in imaging artefacts around the bright sources by factors of 2–3. Applying directional calibration techniques and examining the solutions reveals that the elevated artefacts are imparted by position and time dependent gain drifts with amplitude modulations of up to 50%, consistent with a rotating primary beam of non trivial shape.
منابع مشابه
The Effect of Header Geometry on Temperature Distribution in Cold Rolling
The objectives in the cold rolling process include improved sheet surface quality, enhanced steel mechanical strength, and better solidification operations. Given the increasing demand for higher steel...
متن کاملMagnetic Calibration of Three-Axis Strapdown Magnetometers for Applications in Mems Attitude-Heading Reference Systems
In a strapdown magnetic compass, heading angle is estimated using the Earth's magnetic field measured by Three-Axis Magnetometers (TAM). However, due to several inevitable errors in the magnetic system, such as sensitivity errors, non-orthogonal and misalignment errors, hard iron and soft iron errors, measurement noises and local magnetic fields, there are large error between the magnetometers'...
متن کاملUse of three-dimensional ultrasonography of the eye and measurement of optical long axis in dog
This study was conducted to determine the use of three-dimensional ultrasonography (3DU) in ocular imaging of the dog and measuring of its optical axis. 12 healthy mixed-breed dogs including 6 males and 6 females were studied. 3DU of the eyes were done using a 5–12 MHz linear trapezoid transducer. 3DU of the eyes were evaluated and the normal optical long axis through a line between the cornea ...
متن کاملComparison of the Obtained Results from Two Calibration Methods in MRI Brachytherapy Normoxic Polymer Gel Dosimetry
Introduction: Despite the fact that the clinical implementation of polymer gel dosimetry has been facilitated after the introduction of normoxic gels, there are still complications in its clinical routine use that are under investigation. In the current work, the feasibility of using a normoxic polymer gel dosimeter named MAGICA has been investigated for use in our clinical brachytherapy applic...
متن کاملBrachytherapy polymer gel dosimetry with xCT
ABSTRACTBackground: Polymer gels are an emerging new class of dosimeters which are being applied to the challenges of modern radiotherapy modalities. Research on gel dosimetry involves several scientific domains, one of which is the imaging techniques with which dose data is extracted from the dosimeters. In the current work, we present our preliminary results of investigating capability of X-r...
متن کامل