A novel in vivo corneal trans-epithelial electrical resistance measurement device.
نویسندگان
چکیده
PURPOSE To develop a device that is capable of easily measuring corneal transepithelial electrical resistance (TER) and changes in the corneal barrier function. METHODS We had previously developed an in vivo method for measuring corneal TER using intraocular electrode. This method can be used to precisely measure the decline of the corneal barrier function after instillation of benzalkonium chloride (BAC). In order to lessen the invasiveness of that procedure, we further refined the method for measuring the corneal TER by developing electrodes that could be placed on the cornea and in the conjunctival sac instead of inserting them into the anterior chamber. TER was then calculated by subtracting the electrical resistance, which lacked the corneal epithelial input, from the whole electrical resistance that was measured between the electrodes. Slit lamp examination and scanning electron microscopy (SEM) were used to determine safety of the new device. Corneal TER changes after exposure to 0.02% BAC were determined using the new device as well as SEM and transmission electron microscopy (TEM). RESULTS Slit lamp examination before and after exposure of rabbits' corneas to the sensor confirmed safety of the device. SEM examination revealed no difference of the corneal epithelium which exposed to the new device with normal corneas. SEM and TEM pictures revealed damaged microvilli and tight junctions after instillation of 0.02% BAC. TER change after treatment with 0.02%BAC was similar to those determined by the established anterior chamber method. CONCLUSION We succeeded to develop a less invasive device for corneal TER measurement in vivo in animals. This new device may be applicable in the future for clinical use in humans.
منابع مشابه
Quantitative evaluation of corneal epithelial injury caused by n-heptanol using a corneal resistance measuring device in vivo
PURPOSE We attempted to develop a device for measuring electrical corneal resistance (CR) using corneal contact lens electrodes to quantitatively evaluate corneal injury in vivo. In the present study, full-thickness detachment of the corneal epithelium was induced by n-heptanol, and the feasibility of the quantitative evaluation of this injury by corneal contact lens electrodes was evaluated in...
متن کاملA Novel Resistive Capacitive Feedback Trans-impedance Amplifier Optimization Using IPSO Algorithm
A novel low noise trans-impedance amplifier is proposed using low cost 0.18 µm CMOS technology. A resistive-capacitive feedback is used to extend the bandwidth of the amplifier. As the structure is inductor less, it is suitable for low cost integrated optical interconnects. In this paper Improved Particle Swarm Optimization have applied to determine optimal trans-resistance and noise of propose...
متن کاملVariations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy
Background To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...
متن کاملInfluence of alkyl chain length of benzalkonium chloride on acute corneal epithelial toxicity.
PURPOSE To evaluate acute corneal epithelial toxicity induced by benzalkonium chloride (BAC) homologs with different alkyl chain lengths using an in vivo electrophysiological method. METHODS BAC homologs with C12, C14, and C16 alkyl chain lengths were used at concentrations of 0.0025%, 0.005%, and 0.01%, respectively. Cytotoxicity of BAC homologs on the normal rabbit corneal epithelial cells ...
متن کاملAcute corneal epithelial change after instillation of benzalkonium chloride evaluated using a newly developed in vivo corneal transepithelial electric resistance measurement method.
OBJECTIVE Acute corneal permeability change after instillation of benzalkonium chloride (BAC) was evaluated using a newly developed in vivo corneal transepithelial electric resistance (TER) measurement method. METHOD Corneal TER was measured by Ag/AgCl electrodes placed in the anterior aqueous chamber and on the cornea of live rabbit eyes. TER was measured and TER change after instillation of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of pharmacological and toxicological methods
دوره 76 شماره
صفحات -
تاریخ انتشار 2015