Influence of cyclic variation of right ventricular volume on left ventricular mechanical parameters measured with conductance catheter.
نویسندگان
چکیده
The conductance catheter is widely used for the continuous measurement of the left ventricular (LV) pressure-volume loops. Cyclical change of the right ventricular (RV) volume may alter the parallel conductance volume, thereby affecting the LV mechanical parameters. Using 8 open-chest adult mongrel dogs, multiple LV pressure-volume loops were obtained by 2 methods: first with a vena cava occlusion (VCO) method, which involved RV volume alteration, and second with a right-heart-bypass (RHB) preparation, which decompressed the right ventricle completely. The slope of the end-systolic pressure-volume relation (Ees), the end-systolic volume associated with the end-systolic pressure of 100 mmHg (V100,es), stiffness constant (beta), and the end-diastolic volume associated with the end-diastolic pressure of 9 mmHg (V9,ed) were calculated from each loop. There was minimal influence from RV volume alteration on systolic-phase indices [Ees (VCO method, 6.37 +/- 1.91 mmHg/ml; RHB preparation, 6.60 +/- 1.66mmHg/ml; p=0.356), and V100,es (VCO method, 18.4 +/- 9.3ml; RHB preparation, 17.8 +/- 9.0 ml; p=0.681)], but there was a significant influence on diastolic-phase indices [beta (VCO method, 0.0599 +/- 0.0152; RHB preparation, 0.0839 +/- 0.0150; p=0.007), and V9,ed (VCO method, 35.6 +/- 11.3 ml; RHB preparation, 31.9 +/- 12.3 ml; p=0.001)]. The increase in the RV volume in the diastolic phase increased the parallel conductance volume, causing overestimation of the LV diastolic volume measured by the conductance catheter.
منابع مشابه
The Correlation between Left and Right Ventricular Ejection Fractions in Patients with Ischemic Heart Disease, Documented by Cardiac Magnetic Resonance Imaging
Introduction: The correlation between right and left ventricular ejection fractions (RVEF and LVEF, respectively) has been studied in only a small number of patients with a marked decrease in RVEF and LVEF. The aim of the present study was to compare LVEF and RVEF in patients with ischemic heart disease. RVEF and LVEF were measured by Cardiovascular Magnetic Resonance (CMR) imaging. Materials a...
متن کاملLABORATORY INVESTIGATION VENTRICULAR PERFORMANCE Accuracy of volume measurement by conductance catheter in isolated, ejecting canine hearts
We evaluated the accuracy of the recently reported technique of estimating intraventricular volume by measurement of intracavitary electrical conductance in six isolated, ejecting, canine left ventricles. Left ventricular volumes were measured directly by a previously validated servosystem that employed an electroconductive balloon placed in the left ventricular cavity. The volume measured cont...
متن کاملAccuracy of volume measurement by conductance catheter in isolated, ejecting canine hearts.
We evaluated the accuracy of the recently reported technique of estimating intraventricular volume by measurement of intracavitary electrical conductance in six isolated, ejecting, canine left ventricles. Left ventricular volumes were measured directly by a previously validated servosystem that employed an electroconductive balloon placed in the left ventricular cavity. The volume measured cont...
متن کاملRight ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease
Introduction: In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...
متن کاملAssessment of right ventricular contractile state with the conductance catheter technique in the pig.
OBJECTIVE Since the conductance catheter method has facilitated evaluation of left ventricular contractile state in both laboratory and clinical studies, the aim of this study was to determine whether the technique is similarly useful for the right ventricle. METHODS A series of right ventricular pressure-volume loops was obtained in seven open chest pigs during transient vena caval occlusion...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Japanese circulation journal
دوره 65 8 شماره
صفحات -
تاریخ انتشار 2001