Surface Chemical Etching Behavior of Lr-115 Type Ii Solid State Nuclear Track Detector

نویسندگان

  • VIMAL MEHTA
  • Vimal Mehta
چکیده

Solid State Nuclear Track Detectors (SSNTDs) are well known for the detection of ionizing radiation through track formation of heavy ionizing particles. The LR-115 detector is a commonly used SSNTD for the detection and measurement of Rn and its progeny. Several techniques of track revelation are known but, the chemical etching technique is the most frequently used in which tracks can be made visible under an optical microscope after chemical amplification via etching. So the surface chemical etching behavior of LR-115 polymer is an important parameter in the study of ionizing radiation. The surface chemical behavior is studied by etching process. The parameter studied is the thickness of polymeric sample for different time intervals at different temperatures and normality. The results are indicated in terms of bulk etch rate and an activation energy is determined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Gamma Rays on The Bulk Etching Rate of LR-115 Detector

It is important to measure the bulk-etching rate for any solid state nuclear track detectors, because they have an application in different fields of sciences. The effect of gamma rays emitted from 60 Co source with different doses on LR-115 detector was studied. The bulk etching rate of the detectors was measured before and after irradiation using gamma source. From the results the values of t...

متن کامل

A fast method to measure the thickness of removed layer from etching of SSNTD based on EDXRF

Solid state nuclear track detectors are commonly used for measurements of concentrations of radon gas and/or radon progeny. All these measurements depend critically on the thickness of the removed layer during etching. However, the thickness of removed layer calculated using the etching period does not necessarily provide a su7ciently accurate measure of the thickness. For example, the bulk etc...

متن کامل

Fast and non-destructive determination of active-layer thickness of LR 115 SSNTD using a color commercial document scanner

Measurements using the LR 115 solid-state nuclear track detector (SSNTD) depend critically on the removed thickness of the active layer during etching, which cannot be controlled by the etching period alone. For example, the bulk etch rate depends significantly on the strength of stirring during etching. We propose here a fast, inexpensive and nondestructive method based on a color commercial d...

متن کامل

Bulk etch characteristics of colorless LR 115 SSNTD

The colorless LR 115 solid-state nuclear track detector (SSNTD) (from DOSIRAD) is based on cellulose nitrate and was first studied in view of its applicability in radiobiological experiments with alpha particles. In this paper, the bulk etch characteristics were studied. We first showed that the shape of the alpha-particle tracks are irregular with blurred contours under the optical microscope....

متن کامل

Derivation of V function for LR 115 SSNTD from its partial sensitivity to 222Rn and its short-lived progeny.

Solid-state nuclear track detectors (SSNTDs) have been widely applied for measurements of environmental concentrations of 222Rn and its progeny. The V function for an SSNTD is important for understanding the track development in the SSNTD as well as for real life applications. The partial sensitivity rhoi of the LR 115 detector applied in the bare mode to 222Rn and its short-lived progeny is re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015