Influence of calibration method on distortion-product otoacoustic emission measurements: II. threshold prediction.

نویسندگان

  • Abigail R Rogers
  • Sienna R Burke
  • Judy G Kopun
  • Hongyang Tan
  • Stephen T Neely
  • Michael P Gorga
چکیده

OBJECTIVES Distortion-product otoacoustic emission (DPOAE) stimulus calibrations are typically performed in sound pressure level (SPL) before DPOAE measurements. These calibrations may yield unpredictable DPOAE response levels, presumably because of the presence of standing waves in the ear canal. Forward pressure level (FPL) has been proposed as an alternative method for stimulus calibration because it avoids complications due to standing waves. DPOAE thresholds after four FPL calibrations and one SPL calibration were compared with behavioral thresholds to determine which calibration results in data that yield the highest correlations between the two threshold estimates. DESIGN Fifty-two subjects with normal hearing and 103 subjects with hearing loss participated in this study, with ages ranging from 11 to 75 yr. These were the same individuals whose data were used to address the influence of calibration method on test performance in an accompanying article. DPOAE input/output (I/O) functions were obtained at f2 frequencies of 2, 3, 4, 6, and 8 kHz with the primary frequency ratio fixed at f2/f1 approximately 1.22. L(1) was set according to the equation L(1) = 0.4 L(2) + 39 with L(2) levels ranging from -20 to 70 dB SPL and FPL in 5-dB steps. I/O functions were obtained at each frequency for each of the five stimulus calibrations: SPL, daily FPL at room temperature, daily FPL at body temperature, reference FPL at room temperature, and reference FPL at body temperature. DPOAE thresholds were estimated using two methods. In the first method, DPOAE threshold was taken as the lowest L(2) for which DPOAE level is 3 dB or greater than the noise floor (signal- to-noise ratio > or =3 dB). In a second method, a linear regression method first described by Boege & Janssen (2002) and later adapted by Gorga et al. (2003), all DPOAE levels in each I/O function are converted to linear pressure and extrapolated to 0 microPa, at which the L(2) is taken as threshold. Correlations of DPOAE thresholds with behavioral thresholds were obtained for each frequency, calibration method, and threshold-prediction method. RESULTS Correlations were greatest for frequencies of 3 to 6 kHz and lowest for 8 kHz, consistent with previous frequency effects. Calibration method made little difference in correlations between DPOAE and behavioral thresholds at any frequency. A small difference was noted in correlations for the two threshold prediction methods, with the linear regression method yielding slightly higher correlations at all frequencies. CONCLUSIONS Little difference in threshold correlations was observed among the five calibration methods used to calibrate the stimuli before DPOAE measurements. These results were not anticipated, given the known effects of standing waves on ear-canal estimates of SPL at the plane of the probe. In addition, there was no effect of temperature (body versus room) or timing (daily versus reference) for FPL calibrations. It may be important to note that differences between SPL and FPL calibrations should not be seen if a standing wave does not occur at the plane of the probe at or near the frequency being tested. The frequencies (2 to 8 kHz) were chosen because it was expected that effects from standing waves would occur between these frequencies because of the typical lengths of ear canals for the age group tested. Because measurements were taken at only five discrete frequencies in the interval, it is possible that standing waves were present but did not affect the specific test frequencies. In total, these results suggest that SPL calibrations may be adequate when attempting to predict pure-tone thresholds from DPOAEs, despite the fact that they are known to be susceptible to errors associated with standing waves.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fine Structure in Distortion Product Otoacoustic Emissions and Auditory Perception

4 The influence of the second source of distortion product otoacoustic emissions (DPOAE) on DPOAE input/output functions 41 INTRODUCTION 42 I. EXPERIMENTAL METHODS 45 A. Subjects 45 B. Instrumentation and signal processing 45 C. Calibration 46 D. DPOAE measurements 46 II. DATA ANALYSIS 47 A. Separation of DPOAE components via time windowing 47 B. DPOAE threshold according to Boege and Janssen 5...

متن کامل

Effect of calibration method on distortion-product otoacoustic emission measurements at and around 4 kHz.

OBJECTIVES Distortion-product otoacoustic emissions (DPOAEs) collected after sound pressure level (SPL) calibration are susceptible to standing waves that affect measurements at the plane of the probe microphone due to overlap of incident and reflected waves. These standing-wave effects can be as large as 20 dB, and may affect frequencies both above and below 4 kHz. It has been shown that forwa...

متن کامل

Evaluation of Distortion and Transient Evoked Otoacoustic Emission in Tinnitus Patients with Normal Hearing

Introduction: Tinnitus is a perception of sound without external source. The exact etiology of tinnitus is not fully understood, although some researchers believe that the condition usually starts in the cochlea. The aim of this study was to determine the potential contribution of outer hair cell dysfunction to chronic tinnitus, by application of Distortion-Product Evoked Otoacoustic Emission (...

متن کامل

Chapter 3: Parameters that Influence Pure Tone Threshold Prediction Accuracy with Distortion Product Otoacoustic Emissions and Artificial Neural Networks

The preceding chapter formulated the need for an objective audiologic procedure to aid in the assessment of difficult-to-test populations. Limitations in current objective procedures inspired the ongoing effort to attempt to predict pure tone thresholds (PITs) accurately across a wide frequency range. Despite the complex relation between DPOAEs and PTTs, many researchers turned to distortion pr...

متن کامل

Latency of DPOAE in milliseconds and waves Summary

The latency of Distortion Product Otoacoustic Emissions is defined as the time interval between the wave onset from initial stimulation and the return to the ear canal. Aim: The aim of this research was to verify the latency of the distortion product otoacoustic emissions in normal hearing adults, analyzing the influence of the gender, ear, frequencies and measurements. Study design: clinical p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ear and hearing

دوره 31 4  شماره 

صفحات  -

تاریخ انتشار 2010