Temporal variations in gas temperature in an atomization stage of cadmium and tellurium evaluated by using the two-line method in graphite furnace atomic absorption spectrometry.
نویسندگان
چکیده
In order to discuss the atomization process of an analyte element occurring in a graphite furnace for atomic absorption spectrometry, we measured variations in the characteristic temperature with the progress of an atomization stage, by using a two-line method under the assumption of a Boltzmann distribution. For this purpose, iron was chosen as the analyte element. Also, the atomic absorption of two iron atomic lines, Fe I 372.0 nm and Fe I 373.7 nm, was simultaneously monitored as a probe for the temperature determination. This method enables variations in the gas temperature to be directly traced, yielding a temperature distribution closely related to the diffusion behavior of the probe element in the furnace. This temperature variation was very different from the furnace wall temperatures, which were monitored in conventional temperature control for atomic absorption spectrometry. Correlations between the gas temperature and the charring/atomizing temperatures in the heating program of the furnace were investigated. The atomization of cadmium and tellurium was also investigated by a comparison between the gas temperature with the wall temperature of the furnace. The atomic absorption of cadmium or tellurium appeared to be apart from the absorption of iron while the gas temperature was still low. Therefore, the analyte atoms could be atomized through direct contact with the wall of the graphite furnace, which has a much higher temperature compared to the gas atmosphere during atomization. Their atomization would be caused by conductive heating from the furnace wall rather than by radiant heating in the furnace.
منابع مشابه
Temporal variation in gas temperature at the atomization stage in several types of graphite furnaces for atomic absorption spectrometry.
In order to compare and evaluate the atomization process occurring in several types of graphite furnaces for atomic absorption spectrometry, the authors estimated temporal variations in the gas temperature by using a two-line method under the assumption of a Bolzmann distribution. The atomization furnaces employed were a graphite tube, a graphite tube coated with pyrolitic carbon, a graphite tu...
متن کاملComparative measurement of gas temperature in a graphite atomizer by a two-line method of iron and nickel spectral lines in graphite furnace atomic absorption spectrometry.
The gas temperature of atomospheric gas in a graphite atomizer was measured during an atomization stage in graphite furnace atomic absorption spectrometry (GF-AAS), by using a two-line method under the assumption of Boltzmann distribution. Iron and nickel were chosen as the probe elements to compare the gas temperatures obtained with different pairs of spectral lines. The atomic absorptions of ...
متن کاملMeasuring Conditions for the Determination of Lead in Iron-Matrix Samples Using Graphite Atomizers with/without a Platform in Graphite Furnace Atomic Absorption Spectrometry
In graphite furnace atomic absorption spectrometry (GF-AAS), the atomization process of lead occurring in graphite atomizers with/without a platform plate was investigated when palladium was added to an iron-matrix sample solution containing trace amounts of lead. Absorption profiles of a lead line were measured at various compositions of iron and palladium. Variations in the gas temperature we...
متن کاملRole of a binary metallic modifier in the determination of cadmium in graphite furnace atomic absorption spectrometry.
In order to discuss the matrix modifier effect of palladium, iron, and a mixture of palladium and iron for the determination of cadmium in graphite-furnace atomic absorption spectrometry (GF-AAS), we measured the absorption profiles of a cadmium line at various compositions of these elements. Variations in the gas temperature were also estimated with the progress of atomization, by using a two-...
متن کاملMeasurement of cadmium residues in muscle, liver and kidney of cattle slaughtered in Isfahan abattoir using grafite furnace atomic absorption spectrometry (GFAAS): a preliminary study
The aim of the present study was to determine the levels of cadmium in the muscle, liver and kidney of cattle from Isfahan and to compare the results with those reported by other countries and with the maximum acceptable levels for human consumption. Samples of muscle, liver and kidney from 60 animals aged 1–10- year-old were collected from the carcasses slaughtered at Isfahan abattoir. Samples...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 24 9 شماره
صفحات -
تاریخ انتشار 2008