Normalized quantification of human cytomegalovirus DNA by competitive real-time PCR on the LightCycler instrument.
نویسندگان
چکیده
The development of a novel normalized quantitative competitive real-time PCR on the LightCycler instrument (NQC-LC-PCR) and its application to the quantification of cytomegalovirus (CMV) DNA in clinical samples are described. A heterologous competitor DNA was spiked into test samples and served as an internal amplification control. The internal control (IC) DNA in the test samples was coamplified with the CMV DNA and was tested against a calibrator sample that contained equal amounts of IC DNA and CMV reference standard DNA. An algorithm was developed to normalize possible varying amplification efficiencies between the standard and the samples. After normalization, CMV DNA copy numbers were determined in absolute terms. In a routine clinical setting, normalized quantification by NQC-LC-PCR using a single IC concentration led to results ranging from 500 to 50,000 CMV DNA copies/ml. The results obtained with conventional real-time quantification on the LightCycler instrument were almost identical to those obtained with the NQC-LC-PCR-based quantification. This was the case only for samples in which the PCR was not inhibited. With partially inhibited samples, NQC-LC-PCR was still able to correctly quantify CMV DNA copy numbers even when the PCR was inhibited by about 70%. By analyzing 80 undefined clinical samples, we found that NQC-LC-PCR was suitable for the routine assessment of CMV DNA in clinical plasma samples. Since the ICs were already added to the samples during the DNA purification, almost the entire assay was controlled for sample adequacy. Thus, false negative results were precluded. The NQC-LC-PCR approach developed should be adaptable for additional microbiological applications.
منابع مشابه
Quantification and Optimization of Candida albicans DNA in Blood Samples Using Real- Time PCR
Background: Candida albicans (C. albicans) is a major cause of candidaemia in people with impaired immunity. Blood culture is a “gold standard” for candidaemia detection but is time-consuming and relatively insensitive. We established a real-time PCR assay for C. albicans detection in blood by LightCycler PCR and melting curve analysis. Methods: Five milliliter blood samples from...
متن کاملQuantification of human cytomegalovirus DNA by real-time PCR.
A quantitative real-time PCR assay was developed to measure human cytomegalovirus (HCMV) DNA load in peripheral blood leukocytes (PBLs). The HCMV DNA load in PBLs was normalized by means of the quantification of a cellular gene (albumin). The results of the real-time PCR assay correlated with those of the HCMV pp65-antigenemia assay (P < 0.0001).
متن کاملDifferent real-time PCR formats compared for the quantitative detection of human cytomegalovirus DNA.
BACKGROUND The aim of this study was to compare the ABI PRISM 7700 Sequence Detection System and the LightCycler to develop a quantitative real-time PCR assay for the detection of human cytomegalovirus (HCMV) DNA suitable for routine hospital application. METHODS We used one exonuclease probe and five different hybridization probe sets as sequence-specific fluorescence detection formats. For ...
متن کاملComparison of quantitative competitive PCR with LightCycler-based PCR for measuring Epstein-Barr virus DNA load in clinical specimens.
The aim of this study was to develop a LightCycler-based real-time PCR assay for monitoring the Epstein-Barr virus (EBV) DNA load in unfractionated whole blood. This assay was compared with quantitative competitive PCR (Q-PCR) for EBV. The LightCycler-based assay was highly sensitive and reproducible when quantifying plasmid DNA in either the presence or absence of healthy donor blood DNA. Ampl...
متن کاملDevelopment of a Sensitive Quantitative Competitive PCR Assay for Detection of Human Cytomegalovirus DNA
Accurate and rapid diagnosis of human cytomegalovirus (HCMV) disease in immunocompromised patients has remained as a challenge. Quantitative competitive PCR (QC-PCR) methods for detection of HCMV in these individuals have improved the positive and negative predictive values of PCR for diagnosis of HCMV disease. In this study we used QC-PCR assay, using a co-amplified DNA standard, to quantitate...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 40 12 شماره
صفحات -
تاریخ انتشار 2002