The reliability of frequency-doubling perimetry in young children.
نویسندگان
چکیده
OBJECTIVE To evaluate whether healthy young children are able to perform automated static perimetry reliably using the frequency-doubling technology (FDT) perimeter. DESIGN Prospective, observational case series. PARTICIPANTS Forty healthy children aged 4 to 14 years. TESTING Subjects underwent, in 1 randomly chosen eye, 2 consecutive visual field (VF) tests using the C-20 full-threshold program of the commercially available FDT. MAIN OUTCOME MEASURES Global measures included mean deviation (MD), pattern standard deviation (PSD), test duration and reliability indices, including fixation losses and false-positive and false-negative errors. Fixation losses are checked 6 times throughout the examination, rather than being continuously monitored. Two scoring systems, based on the total deviation probability plot, classified each VF as normal or abnormal. RESULTS All subjects completed the VF test. The better of 2 examinations (as determined by the MD score) was used for analysis. The average test duration was 4.9+/-0.7 minutes for the entire group. The mean MD and PSD were -0.78+/-4.9 and 6.7+/-6.2, respectively. A clear correlation to age was found for MD, PSD, abnormality of the VF, and test duration (all P<0.05). Of all VFs, 32.5% were unreliable, such that at younger than 8 years of age, 42.9% of the VFs were unreliable, compared with 23.1% for those older than 8 years. Younger than 8 years of age, 78.6% of VFs were abnormal, whereas for ages 8 years and older, 26.9% of VFs were abnormal. CONCLUSIONS Frequency-doubling technology seems to be a clinically feasible VF method for evaluating young children older than approximately 8 years of age. The reliability indices, MD, test duration, and the reproducibility of the VF test were found to be highly correlated with age, in such a way that these parameters all improved with increasing age.
منابع مشابه
Comparison of visual field test results obtained through Humphrey matrix frequency doubling technology perimetry versus standard automated perimetry in healthy children
AIMS The aim of this study was to compare the visual field test results in healthy children obtained via the Humphrey matrix 24-2 threshold program and standard automated perimetry (SAP) using the Swedish interactive threshold algorithm (SITA)-Standard 24-2 test. MATERIALS AND METHODS This prospective study included 55 healthy children without ocular or systemic disorders who underwent both S...
متن کاملSignificance of the Reliability Coefficient in Frequency Doubling Technology Perimetry-Based Mass Screening
Cite this article: Nakano T, Nakagawa T, Tatemichi M (2017) Significance of the Reliability Coefficient in Frequency Doubling Technology Perimetry-Based Mass Screening. JSM Ophthalmol 5(1): 1048. *Corresponding author Tadashi Nakano, Department of Ophthalmology, The Jikei University, School of Medicine, 3-19-18 NishiShimbashi Minato-ku Tokyo 105-8471, Japan, Tel: 81-3-3433-1111(ext. 3581); Fax:...
متن کاملComparison of visual evoked potentials, automated perimetry and frequency-doubling perimetry in early detection of glaucomatous visual field loss.
The present study compares frequency-doubling perimetry (FDP), automated perimetry (AP) and visual evoked potentials (VEP) for their ability to diagnose early glaucoma. In present study 224 patients of Clinic for Eye Diseases, Clinical Hospital "Sestre Milosrdnice" that had diagnosis of open angle glaucoma and glaucomatous visual field loss proven by automated static perimetry on only one eye w...
متن کاملTest-retest variability of frequency-doubling perimetry and conventional perimetry in glaucoma patients and normal subjects.
PURPOSE To compare the test-retest variability characteristics of frequency-doubling perimetry, a new perimetric test, with those of conventional perimetry in glaucoma patients and normal control subjects. METHODS The study sample contained 64 patients and 47 normal subjects aged 66.16+/-11.86 and 64.26+/-7.99 years (mean +/- SD), respectively. All subjects underwent frequency-doubling perime...
متن کاملFrequency Doubling Perimetry
DOS Times Vol. 11, No. 6 December, 2005 The goal of perimetry is to establish an accurate estimate of visual field sensitivity. Perimetry is performed to detect early visual field defects, determine specific patterns of visual field loss for differential diagnosis and monitor for evidence of progression of field loss. Conventionally Standard Achromatic Perimetry (SAP) has been used to achieve t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmology
دوره 111 3 شماره
صفحات -
تاریخ انتشار 2004