Continuous Flow Experimental Set-Up for Fouling Deposit Study

نویسندگان

  • A. L. Ho
  • N. Ab. Aziz
  • F. S. Taip
  • M. N. Ibrahim
چکیده

The study of the fouling deposition of pink guava juice (PGJ) is relatively new research compared to milk fouling deposit. In this work, a new experimental set-up was developed to imitate the fouling formation in heat exchanger, namely a continuous flow experimental set-up heat exchanger. The new experimental setup was operated under industrial pasteurization temperature of PGJ, which was at 93°C. While the flow rate and pasteurization period were based on the experimental capacity, which were 0.5 and 1 liter/min for the flow rate and the pasteurization period was set for 1 hour. Characterization of the fouling deposit was determined by using various methods. Microstructure of the deposits was carried out using ESEM. Proximate analyses were performed to determine the composition of moisture, fat, protein, fiber, ash and carbohydrate content. A study on the hardness and stickiness of the fouling deposit was done using a texture analyzer. The presence of seedstone in pink guava juice was also analyzed using a particle analyzer. The findings shown that seedstone from pink guava juice ranging from 168 to 200μm and carbohydrate was found to be a major composition (47.7% of fouling deposit consists of carbohydrate). Comparison between the hardness and stickiness of the deposits at two different flow rates showed that fouling deposits were harder and denser at higher flow rate. Findings from this work provide basis knowledge for further study on fouling and cleaning of PGJ. Keywords—Pink guava juice, fouling deposit, heat exchanger.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fouling of Milk Components with Varying Surface and Process Parameters

In this work two approaches against milk fouling in plate heat exchangers were investigated: (i) the temporary increase of the shear forces acting on the surface by superimposing an oscillating flow on the steady flow and thus increasing the mechanical flow forces and (ii) the modification of the energetic surface properties to reduce the adhesive strength between deposit and heat transfer surf...

متن کامل

Experimental measurement of heat transfer coefficient and mass of deposited CaSO4 in subcooled flow boiling condition

Fouling is a common, fundamental and costly problem in heat transfer systems, which reduces thermal efficiency of equipment, increases the energy loss and causes strong damage to the heat transfer equipment in various industries. The main causes of fouling on the heat transfer surfaces are salts with inverse temperature-solubility in the fluid which calcium sulfate is one of the most important ...

متن کامل

Fouling of a hollow fibre submerged membrane during long- term filtration of activated sludge

Membrane fouling in membrane bioreactors (MBR) is caused by cake formation on the surface, mainly attributed to suspended solids, and also by surface adsorption connected with pore blocking, attributed to soluble components of activated sludge. In this study, long-term experiments were carried out in sub-critical conditions with frequent backwashing, and the nature of fouling was investigated. ...

متن کامل

Reuse of Refinery Treated Wastewater in Cooling Towers

In this report, experimental investigation of waste water treatment by reverse osmosis to enable its reuse in cooling tower is presented. A polyamide spiral wound RO membrane followed by three filters as RO pretreatment (two activated carbon and one cartridge filter) and samples of Tehran refinery treated waste water have been used. The effect of operating conditions such as pressure differ...

متن کامل

Challenges in Cleaning Microstructured Devices

Continuous crystallization of lipid nanoparticles, carrying bioactive compounds, is employed as model system for food products to demonstrate benefits, application possibilities and challenges of microscale process engineering. It could be shown, that high and well-defined cooling rates (up to 104 times higher compared to the standard batch process) can be achieved by using a micro heat exchang...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012