Echocardiographic Evaluation of Hemodynamics in Patients With Systolic Heart Failure Supported by a Continuous-Flow LVAD.
نویسندگان
چکیده
BACKGROUND Hemodynamics assessment is important for detecting and treating post-implant residual heart failure, but its accuracy is unverified in patients with continuous-flow left ventricular assist devices (CF-LVADs). OBJECTIVES We determined whether Doppler and 2-dimensional transthoracic echocardiography reliably assess hemodynamics in patients supported with CF-LVADs. METHODS Simultaneous echocardiography and right heart catheterization were prospectively performed in 50 consecutive patients supported by using the HeartMate II CF-LVAD at baseline pump speeds. The first 40 patients were assessed to determine the accuracy of Doppler and 2-dimensional echocardiography parameters to estimate hemodynamics and to derive a diagnostic algorithm for discrimination between mean pulmonary capillary wedge pressure ≤15 versus >15 mm Hg. Ten patients served as a validation cohort. RESULTS Doppler echocardiographic and invasive measures of mean right atrial pressure (RAP) (r = 0.863; p < 0.0001), systolic pulmonary artery pressure (sPAP) (r = 0.880; p < 0.0001), right ventricular outflow tract stroke volume (r = 0.660; p < 0.0001), and pulmonary vascular resistance (r = 0.643; p = 0.001) correlated significantly. Several parameters, including mitral ratio of the early to late ventricular filling velocities >2, RAP >10 mm Hg, sPAP >40 mm Hg, left atrial volume index >33 ml/m(2), ratio of mitral inflow early diastolic filling peak velocity to early diastolic mitral annular velocity >14, and pulmonary vascular resistance >2.5 Wood units, accurately identified patients with pulmonary capillary wedge pressure >15 mm Hg (area under the curve: 0.73 to 0.98). An algorithm integrating mitral inflow velocities, RAP, sPAP, and left atrial volume index was 90% accurate in distinguishing normal from elevated left ventricular filling pressures. CONCLUSIONS Doppler echocardiography accurately estimated intracardiac hemodynamics in these patients supported with CF-LVAD. Our algorithm reliably distinguished normal from elevated left ventricular filling pressures.
منابع مشابه
Advances in Mechanical Circulatory Support Imaging for Ventricular Function and Myocardial Recovery on Nonpulsatile Ventricular Assist Devices
Advances in the field of device support have led to increased use of continuous-flow left ventricular assist devices (LVADs) to improve outcomes in patients with end-stage heart disease. Newer-generation LVADs have become the pump of choice for bridging to heart transplantation and as destination therapy for patients with contraindications to transplantation.1 Different imaging modalities have ...
متن کاملRole of echocardiography in patients with intravascular hemolysis due to suspected continuous-flow LVAD thrombosis.
OBJECTIVES This study sought to characterize the echocardiographic findings of patients presenting with intravascular hemolysis (IVH) due to suspected continuous-flow left ventricular assist device (LVAD) pump thrombosis. BACKGROUND LVAD patients who develop pump thrombosis often present with IVH. Echocardiography may be able to detect device dysfunction in this setting. METHODS Continuous-...
متن کاملFocused Review on Transthoracic Echocardiographic Assessment of Patients with Continuous Axial Left Ventricular Assist Devices
Left ventricular assist devices (LVADs) are systems for mechanical support for patients with end-stage heart failure. Preoperative, postoperative and comprehensive followup with transthoracic echocardiography has a major role in LVAD patient management. In this paper, we will present briefly the hemodynamics of axial-flow LVAD, the rationale, and available data for a complete and organized echo...
متن کاملImaging for ventricular function and myocardial recovery on nonpulsatile ventricular assist devices.
Advances in the field of device support have led to increased use of continuous-flow left ventricular assist devices (LVADs) to improve outcomes in patients with end-stage heart disease. Newer-generation LVADs have become the pump of choice for bridging to heart transplantation and as destination therapy for patients with contraindications to transplantation.1 Different imaging modalities have ...
متن کاملCorrelation between Hyponatremia and High Risk Clinical and Echocardiographic Features in Patients with Acute Heat Failure
Background and purpose: Heart failure (HF) is characterized by decreased ability of the heart to provide sufficient blood flow or fill with the blood. Hyponatremia is the most commonly seen electrolyte abnormality in patients with heart failure that is associated with increased morbidity and mortality. The aim of this study was to assess the correlation between hyponatremia and high risk clinic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American College of Cardiology
دوره 64 12 شماره
صفحات -
تاریخ انتشار 2014