Numerical Prediction of Heat-flux to Massive Calorimeters Engulfed in Regulatory Fires with the Cask Analysis Fire Environment (cafe) Model

نویسندگان

  • J. A. Koski
  • Carlos Lopez
چکیده

Recent observations show that the thermal boundary conditions within large-scale fires are significantly affected by the presence of thermally massive objects. These objects cool the soot and gas near their surfaces, and these effects reduce the incoming radiant heat-flux to values lower than the levels expected from simple σTfire models. They also affect the flow and temperature fields in the fire far from their surfaces. The Cask Analysis Fire Environment (CAFE) code has been developed at Sandia National Laboratories to provide an enhanced fire boundary condition for the design of radioactive material packages. CAFE is a set of computer subroutines that use computational fluid mechanics methods to predict convective heat transfer and mixing. It also includes models for fuel and oxygen transport, chemical reactions, and participating-media radiation heat transfer. This code uses two-dimensional computational models so that it has reasonably short turnaround times on standard workstations and is well suited for design and risk studies. In this paper, CAFE is coupled with a commercial finite-element program to model a large cylindrical calorimeter fully engulfed in a pool fire. The time-dependent heat-flux to the calorimeter and the calorimeter surface temperature are determined for several locations around the calorimeter circumference. The variation of heat-flux with location is determined for calorimeters with different diameters and wall thicknesses, and the observed effects discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of an Experiment to Measure Heat Transfer to a Massive Object Engulfed in a Full Scale Regulatory Fire

This paper describes the design of a full-scale experiment to measure the heat transfer from a large pool fire to an engulfed 1.2 m diameter, 2.54 cm wall thickness hollow cylindrical calorimeter. This work is focused at determining whether temperature measurements made on the interior calorimeter surface can be used with a one-dimensional inverse conduction solver to accurately determine the h...

متن کامل

Fire Tests and Analyses of a Rail Cask-Sized Calorimeter

Three large open pool fire experiments involving a calorimeter the size of a spent fuel rail cask were conducted at Sandia National Laboratories’ Lurance Canyon Burn Site. These experiments were performed to study the heat transfer between a very large fire and a large cask-like object. In all of the tests, the calorimeter was located above the center of a 7.93m diameter fuel pan, elevated 1m a...

متن کامل

Development and Use of the CAFE-3D Code for Analysis of Radioactive Material Packages in Fire Environments

A computational fluid dynamics (CFD) based fire model has been successfully coupled to standard finite-element computer codes in order to permit design and risk analysis of radioactive material packages. The fire model, called Container Analysis Fire Environment (CAFE), is based on a three-dimensional finite volume formulation of basic fire chemistry and fluid dynamics. The fire model includes ...

متن کامل

Safety Analysis of Spent Fuel Transportation Cask of Bushehr Nuclear Power Plant through the Passing of Fire Tunnel with ANSYS®10.0

The spent fuel assemblies (FAs) of Bushehr Nuclear Power Plant are planed to be transported by TK-13 casks. Each spent fuel transportation cask holds 12 spent FAs and has a thick steel container to provide shielding. The calculations have been performed for FAs with burn ups of 60 MWd/kg and a 3-years cooling period. The ANSYS®10.0 general finite element analysis package was se...

متن کامل

Measurements of Heat Transfer to a Massive Cylindrical Object Engulfed in a Regulatory Pool Fire

A series of large-scale experiments were performed to measure heat transfer to a massive cylindrical calorimeter engulfed in a 30-minute circular-pool fire. The calorimeter inner surface temperature and the flame black body emissive power were measured at several locations as functions of time. An inverse conduction technique was used to determine the net heat flux to the calorimeter. Light win...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000