Noninvasive pulse waveform analysis in clinical trials: similarity of two methods for calculating aortic systolic pressure.
نویسندگان
چکیده
BACKGROUND Concerns persist about the validity of generalized transfer function-derived, aortic blood-pressure measurements during the administration of vasoactive agents in clinical trials. Hence, we compared this transfer-function method with another, which estimates aortic systolic pressure directly from the late systolic shoulder of the radial pressure wave, after administration of placebo, ramipril, or atenolol. METHODS We recorded radial pressure pulse waveforms, using a commercially available system, in 30 subjects with >or=1 coronary risk factor in an acute study of ramipril at 10 mg and atenolol at 100 mg. Directly recorded radial and derived aortic pressure pulse waveforms were examined individually and were ensemble-averaged, and the difference between radial and aortic pressure responses was examined. RESULTS The late systolic shoulder response from radial waveforms was reduced by 15.8 mm Hg (SD, 12.2 mm Hg) more with ramipril than with atenolol. This was similar to a difference of 14.6 mm Hg (SD, 11.2 mm Hg) calculated for the aortic systolic pressure response using the transfer-function technique. Ramipril caused a greater reduction in the aortic systolic pressure response (22.2 mm Hg), whereas with atenolol, there was a modest decrease (7.6 mm Hg). The mean difference between aortic systolic pressures measured from direct radial waveforms and from derived aortic pressure between 3 and 5 h after dosing under all circumstances was 1.6 mm Hg (SD, 8.9 mm Hg). CONCLUSIONS Central pressure derived from radial pressure waveforms using a generalized transfer function gave similar results for central pressure measured directly from radial waveforms. The hemodynamic benefits of angiotensin-converting enzyme inhibitor, angiotensin receptor blocker, and calcium channel blocker over beta-blocker antihypertensive therapy in recent trials were confirmed by this study.
منابع مشابه
Pulse wave analysis of the aortic pressure waveform in severe left ventricular systolic dysfunction.
BACKGROUND The effect of moderate left ventricular systolic dysfunction (LVSD) on ventricular/vascular coupling and the aortic pressure waveform (AoPW) has been well described, but the effect of severe LVSD has not. METHODS AND RESULTS We used noninvasive, high-fidelity tonometry of the radial artery and a mathematical transfer function to generate the AoPW in 25 treated patients with LVSD (m...
متن کاملCARDIOVASCULAR MEDICINE Quantification of glyceryl trinitrate effect through analysis of the synthesised ascending aortic pressure waveform
Objective: To establish through analysis of the radial pressure pulse waveform the dose dependent effects of glyceryl trinitrate (GTN) on properties of different blood vessels. Design: Radial pulse waveform was measured in randomised order before, during a five hour application of a GTN patch delivering 0.104–0.625 mg/h, and for two hours after patch removal. The radial pressure waveform (Milla...
متن کاملQuantification of glyceryl trinitrate effect through analysis of the synthesised ascending aortic pressure waveform.
OBJECTIVE To establish through analysis of the radial pressure pulse waveform the dose dependent effects of glyceryl trinitrate (GTN) on properties of different blood vessels. DESIGN Radial pulse waveform was measured in randomised order before, during a five hour application of a GTN patch delivering 0.104-0.625 mg/h, and for two hours after patch removal. The radial pressure waveform (Milla...
متن کاملPulse wave analysis: what do the numbers mean?
Applanation tonometry, a simple noninvasive technique for recording a high-fidelity waveform from an accessible pulse, has facilitated pulse wave analysis in large population studies. Most interest has focused on estimating an aortic or “central” waveform by the application of a filter or generalized transfer function applied to a radial waveform.1 Systolic pressure and pulse pressure differ be...
متن کاملA System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...