The design and performance of an ion trap storage-reflectron time-of-flight mass spectrometer

نویسندگان

  • Benjamin M. Chien
  • Steven M. Michael
  • David M. Lubman
چکیده

The design and performance of an ion trap storage-reflectron time-of-flight mass spectrometer (IT-RETOF MS) combination have been explored for detection of ions generated from both internal and external ionization sources. Ions were generated inside the trap using laser-induced resonance enhanced multiphoton ionization at 266 nm, while ions were generated external to the trap using either an atmospheric pressure or low pressure d.c. plasma source or an electrospray ionization source. It is demonstrated herein that the ion trap provides an effective means of storing ions from 10 ps up to 10 s prior to mass analysis via pulsed d.c. extraction into the RETOF MS device. In addition, it is shown that the storage capabilities of the device provide enhanced resolution and sensitivity as the storage time is increased. A resolution of nearly 2100 at m/z 93 is demonstrated using external injection from the atmospheric pressure dc. plasma source when a storage time of 9 s is used before ejection. Further, a resolution of =3300 at m/z 1000 is demonstrated using external injection from an electrospray ionization source into the trap with a storage time of 931 ms. The IT-RETOF storage capabilities are shown to provide the potential for nearly 100% duty cycle in converting a continuous ion beam into a pulsed source for TOF. The detection limit of the device is demonstrated with liquid injection techniques for a typical sample and found to be in the low femtomole range. In addition, the r.f. voltage was shown to be an effective means of eliminating low mass background ions from the trap and, thus, from the TOF mass spectra obtained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An ion trap storage/time-of-flight mass spectrometer

An ion trap/time-of-flight (TOF) mass spectrometer combination has been developed in order to combine the storage capabilities of an ion trap with the speed and resolution of a time-of-flight device. The ion trap is an rf quadrupole trap which operates in the total storage mode, i.e., with the dc voltage=0 on the end caps and rf voltage on the ring electrode. The trap has an ion storage time of...

متن کامل

Development of a capillary high-performance liquid chromatography tandem mass spectrometry system using SWIFT technology in an ion trap/reflectron time-of-flight mass spectrometer.

In this work a capillary high-performance liquid chromatography/tandem mass spectrometry system has been developed in a quadrupole ion trap/reflectron time-of-flight mass spectrometer. The broadband excitation for isolating a precursor ion is achieved by generating the stored waveform inverse Fourier transform waveform in real time. Following the isolation and cooling periods, an auxiliary AC v...

متن کامل

On-line Capillary Separations/Tandem Mass Spectrometry for Protein Digest Analysis by Using an Ion Trap Storage/Reflectron Time-of- Flight Mass Detector

Capillary separations interfaced to tandem mass spectrometry provide a very powerful tool for the characterization of biological macromolecules such as proteins and peptides. The development of real time data-dependent data acquisition has further enhanced the capability of this method. However, the application of this technique to fast capillary separations has been limited by the relatively s...

متن کامل

The Use of On-line Capillary Electrophoresis/Electrospray Ionization with Detection via an Ion Trap Storage/Reflection Time-of-flight Mass Spectrometer for Rapid Mutation-site Analysis of Hemoglobin Variants

Capillary electrophoresis/electrospray ionization using an ion trap storage/reflectron time-of-flight mass spectrometer detector (CE/ESI-IT/reTOF) is used to provide a rapid and sensitive method for analyzing structural variants in the hemoglobin (Hb) â-chain. The Hb αand â-chains are separated and the â-chain is digested by trypsin. The digest is analyzed by CE/ESI-IT/reTOF where a comparison ...

متن کامل

Ion trap/ion mobility/quadrupole/time-of-flight mass spectrometry for peptide mixture analysis.

An ion trap/ion mobility/quadrupole/time-of-flight mass spectrometer has been developed for the analysis of peptide mixtures. In this approach, a mixture of peptides is electrosprayed into the gas phase. The mixture of ions that is created is accumulated in an ion trap and periodically injected into a drift tube where ions separate according to differences in gas-phase ion mobilities. Upon exit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001