Internal jugular vein occlusion test for rapid diagnosis of misplaced subclavian vein catheter into the internal jugular vein.
نویسندگان
چکیده
BACKGROUND During subclavian vein catheterization, the most common misplacement of the catheter is cephalad, into the ipsilateral internal jugular vein (IJV). This can be detected by chest radiography. However, after any repositioning of the catheter, subsequent chest radiography is required. In an effort to simplify the detection of a misplaced subclavian vein catheter, the authors assessed a previously published detection method. METHODS One hundred adult patients scheduled for subclavian vein cannulation were included in this study. After placement of subclavian vein catheter, chest radiography was performed. While the x-ray film was being processed, the authors performed an IJV occlusion test by applying external pressure on the IJV for approximately 10 s in the supraclavicular area and observed the change in central venous pressure and its waveform pattern. The observations thus obtained were compared with the position of catheter in chest radiographs, and the sensitivity and specificity of this method were evaluated using a 2 x 2 table. RESULTS In 96 patients, subclavian vein cannulation was successfully performed. In four patients, cannulation was unsuccessful; therefore, these patients were excluded from the study. There were six misplacements of venous catheters as detected by radiography. In five (5.2%) patients, the catheter tip was located in the ipsilateral IJV, and in one (1.02%), the catheter tip was located in the contralateral subclavian vein. In the patients who had a misplaced catheter into the IJV, IJV occlusion test results were positive, with an increase of 3-5 mmHg in central venous pressure, whereas the test results were negative in patients who had normally placed catheters or misplacement of a catheter other than in the IJV. There were no false-positive or false-negative test results. CONCLUSION The IJV occlusion test successfully detects the misplacement of subclavian vein catheter into the IJV. However, it does not detect any other misplacement. The test may allow avoidance of repeated exposure to x-rays after catheter insertion and repositioning.
منابع مشابه
Facial Vein Draining Into External Jugular vein (Case Report)
Purpose: Circulatory system is very important because of injection, Blood transfer and centeral venous catheter insertion. The superficial veins, especially the external jugular vein (EJV) are increasingly being utilized for cannulation to conduct diagnostic procedures or intravenous therapies. The anomalous drainage of veins is of great significance for vascular surgeons and reconstructive sur...
متن کاملThe Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections
Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...
متن کاملSubclavian vein dialysis access catheter-complications are low.
Internal jugular vein has been recommended as the vascular access for haemodialysis because it is associated with less thrombotic/stenotic complication. Despite this recommendation, subclavian vein access is still being frequently used. This paper aims at reviewing the rate of complications associated with temporary double lumen subclavian vein dialysis access catheter in a personal series. It ...
متن کاملMisplaced subclavian central venous catheter
Percutaneous Central Venous Catheter (CVC) insertion using internal jugular and Subclavian veins routes is common procedure for all intensive care admitted patients and some patients in the ward as demand arises in central and referral hospitals of Botswana. This is a case report of a patient on whom a third attempt of re-inserting a CVC for fluid and total parenteral nutrition (TPN) was made. ...
متن کاملCatheter Displacement into Inferior Epigastric Vein Causing Local Phlebitis and Cellulitis
Catheter insertion for intravenous hyperalimentation is a commonly and widely used clinical technique. When compared with the incidence of complications associated with insertions into the internal jugular vein or the subclavian vein, complications associated with insertions into the femoral vein are less frequent. In this paper, we describe a very rare complication of femoral vein catheter ins...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 95 6 شماره
صفحات -
تاریخ انتشار 2001