Extending the dynamic range of nuclear pulse spectrometers.

نویسندگان

  • A Pullia
  • F Zocca
  • G Pascovici
  • D Bazzacco
چکیده

Using an innovative time-varying front-end electronics in conjunction with a bulky coaxial high-purity germanium detector, we were able to extend the range of the radionuclide spectra well beyond the analog to digital converter (ADC) saturation point. The electronics automatically conditions the signal for digital-filtering optimization if it is in the ADC voltage range and for time-over-threshold analysis if it exceeds the ADC range. A high spectroscopic resolution has been achieved in both operation ranges. An unprecedented wide energy range from 5 keV to 150 MeV of equivalent energy, or 90 dB, has been obtained using a single acquisition chain, while maintaining a high-energy resolution in the whole spectrum. For example, with an ADC range of 3 MeV a resolution has been obtained of 1.3/2.2 keV full width at half maximum on the 122/1332 keV gamma-ray lines of 57Co and 60Co, and of <0.4% in the time-over-threshold region, or for energy deposits beyond 3 MeV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extending the Radar Dynamic Range using Adaptive Pulse Compression

The matched filter in the radar receiver is only adapted to the transmitted signal version and its output will be wasted due to non-matching with the received signal from the environment. The sidelobes amplitude of the matched filter output in pulse compression radars are dependent on the transmitted coded waveforms that extended as much as the length of the code on both sides of the target loc...

متن کامل

Seismic Fragility Assessment of Steel SMRF Structures under Various Types of Near Fault Forward Directivity Ground Motions

In this paper, the seismic collapse probability of special steel moment-resisting frame (SSMRF) structures under near fault pulse-like and far fault ordinary ground motions is evaluated through fragility analysis. For this purpose, five sample frames with 3 to 15 stories are designed and imposed to the ground motion excitations with different characteristics. Fragility curves are derived for th...

متن کامل

A technique for extending by ∼10(3) the dynamic range of compact proton spectrometers for diagnosing ICF implosions on the National Ignition Facility and OMEGA.

Wedge Range Filter (WRF) proton spectrometers are routinely used on OMEGA and the NIF for diagnosing ρR and ρR asymmetries in direct- and indirect-drive implosions of D(3)He-, D2-, and DT-gas-filled capsules. By measuring the optical opacity distribution in CR-39 due to proton tracks in high-yield applications, as opposed to counting individual tracks, WRF dynamic range can be extended by 10(2)...

متن کامل

Non-linear Response and Dynamic Buckling Analysis of a Cylindrical Sandwich Panel with a Flexible Core under Blast Loading

In this paper, three-dimensional displacement response of a cylindrical sandwich panel with compressible core under the action of dynamic pulse loading is addressed using the extended high order sandwich panel theory. Also, local dynamic pulse buckling of facesheets is studied by considering the Budiansky-Roth buckling criterion. It is assumed that the sandwich panels consist of orthotropic fac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 79 3  شماره 

صفحات  -

تاریخ انتشار 2008