A multireflection cell for enhanced absorbance detection in microchip-based capillary electrophoresis devices.
نویسندگان
چکیده
The design, fabrication and testing of a photolithographically fabricated, glass-based multireflection absorbance cell for microfluidic devices, in particular microchip-based capillary electrophoresis (CE) systems is described. A multireflection cell was fabricated lithographically using a three-mask process to pattern aluminum mirrors above and below a flow channel in a chip, with 30 microm diameter optical entrance or exit apertures (one in each mirror) positioned 200 microm apart. Source and detector were positioned on opposite sides, and the metal mirrors were made 1 cm square, to reduce stray light effects. Calibration curves using bromothymol blue (BTB) with a 633 nm source (He:Ne laser) were linear to at least 0.5 absorbance units, with typical r2 values of 0.9997, relative standard deviations in the slopes of +/- 1.3%, and intercepts of zero within experimental error. Effective optical pathlengths of 50-272 microm were achieved, compared to single-pass pathlengths of 10-30 microm, corresponding to sensitivity enhancements (i.e., optical path length increase) of 5 to 10-fold over single-pass devices. Baseline absorbance noise varied within a factor of two in almost all devices, depending only weakly on path length. This device can give much higher absorbance sensitivity, and should be much easier to manufacture than planar, glass-based devices previously reported.
منابع مشابه
Recent Advances in Portable Analytical Electromigration Devices
This article presents an overview of recent advances in the field of portable capillary electrophoresis and microchip electrophoresis equipment during the period 2013–Mid 2015. Instrumental achievements in the separation as well as the detection part of the equipment are discussed. Several applications from a variety of fields are described.
متن کاملFabrication of microfluidic devices using dry film photoresist for microchip capillary electrophoresis.
An inexpensive, disposable microfluidic device was fabricated from a dry film photoresist using a combination of photolithographic and hot roll lamination techniques. A microfluidic flow pattern was prefabricated in a dry film photoresist tape using traditional photolithographic methods. This tape became bonded to a poly(methyl methacrylate) (PMMA) sheet with prepouched holes when passed throug...
متن کاملExperimental and Numerical Analysis of High-Resolution Injection Technique for Capillary Electrophoresis Microchip
This study presents an experimental and numerical investigation on the use of high-resolution injection techniques to deliver sample plugs within a capillary electrophoresis (CE) microchip. The CE microfluidic device was integrated into a U-shaped injection system and an expansion chamber located at the inlet of the separation channel, which can miniize the sample leakage effect and deliver a h...
متن کاملIntegrated hybrid polystyrene-polydimethylsiloxane device for monitoring cellular release with microchip electrophoresis and electrochemical detection.
In this work, a polystyrene (PS)-polydimethylsiloxane (PDMS) hybrid device was developed to enable the integration of cell culture with analysis by microchip electrophoresis and electrochemical detection. It is shown that this approach combines the fundamental advantages of PDMS devices (the ability to integrate pumps and valves) and PS devices (the ability to permanently embed fluidic tubing a...
متن کاملAnalysis of explosives via microchip electrophoresis and conventional capillary electrophoresis: a review.
The upsurge in terrorist activity has generated tremendous demand for innovative tools capable of detecting major industrial, military, and home-made (improvised) explosives. Fast, sensitive, and reliable detection of explosives in the field is a very important issue in nowadays. CE, especially in its miniaturized format (lab-on-a-chip), offers great possibilities to create portable, field depl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Electrophoresis
دوره 21 7 شماره
صفحات -
تاریخ انتشار 2000