Measuring circulating blood volume in newborn infants using pulse dye densitometry and indocyanine green.
نویسندگان
چکیده
BACKGROUND Circulating blood volume (BV) is an important, but often unconsidered, variable in newborn infants undergoing intensive care. The data on validation and repeatability of BV measurement are limited. AIM To validate and test the repeatability of measuring BV in newborn infants using indocyanine green (ICG) and pulse dye densitometry (PDD). METHODS Validation--Paired measurements of BV were made using the fetal hemoglobin (HbF) dilution and the PDD method. Repeatability--The BV was measured twice at an interval of 30-40 min in a second group of infants. RESULTS Validation--Data from three of 13 infants studied were excluded because of probe dislodgement or ICG injection error. The median (range) birth weight of the 10 infants whose data were analyzed was 1032 g (740-2384 g) and seven (70%) were receiving either mechanical ventilation or nasal CPAP. The median BV measured by HbF dilution was 66.2 ml x kg(-1) (43.7-81.0 ml x kg(-1)) and by the PDD method was 68.9 ml x kg(-1) (49.3-101.0 ml x kg(-1)). The mean difference was 5.92 ml x kg(-1) (SD 17.33 ml x kg(-1)). Repeatability--Twelve infants were studied and three excluded because of probe dislodgement/motion artifact or ICG injection error. The median weight of the nine infants whose data were analyzed was 1208 g (795-2600 g). The median (range) BV1 and BV2 were 70.5 ml x kg(-1) (53.1-160 ml x kg(-1)) and 87.5 ml x kg(-1) (38.0-248.0 ml x kg(-1)), respectively. Mean difference of the two BV estimates (BV1-BV2) was -24.6 ml x kg(-1) (SD 33.3 ml x kg(-1)) and coefficient of repeatability was 66.5 ml x kg(-1). CONCLUSION Pulse dye densitometry can be used to measure BV in the newborn infant at the cotside but the repeatability measurements suggest that its use is limited.
منابع مشابه
Pulse dye densitometry: a novel bedside monitor of circulating blood volume.
INTRODUCTION Monitoring of circulating blood volume is important in the management of critically ill patients. Current methods of circulating blood volume measurements such as indicator dilution using radioisotopes or Evans blue dye are unsuitable for clinical application as these tests do not allow for frequent repeated measurements to be done. A direct bedside measurement of circulating blood...
متن کاملCerebral distribution of cardiac output in newborn infants.
Cerebral blood flow and output of the left ventricle were simultaneously investigated in 17 infants using multichannel near infrared spectroscopy and pulse dye densitometry with indocyanine green. Cardiac output and cerebral blood flow were positively related. The control of cardiac output is important in the regulation of cerebral blood flow in infants.
متن کاملNoninvasive measurement of cerebral blood flow in adults using near-infrared spectroscopy and indocyanine green: a pilot study.
This pilot study was designed to determine the feasibility of measuring cerebral blood flow noninvasively after an intravenous bolus of indocyanine green using near-infrared spectroscopy and pulse dye-densitometry. Feasibility aside, this study did not attempt to validate the measured values of cerebral blood flow against an established method of measurement. Twelve healthy volunteers were inve...
متن کاملMeasurement of plasma volume in neonates.
There is no reliable and safe method for measuring plasma volume in ill newborn infants. We describe an adaptation of the dye dilution technique using indocyanine green as the plasma label, which can be used in the sickest and smallest of infants with the minimum of disturbance. To avoid the need to take large volumes of blood from the infant, samples were diluted 1:1 with distilled water and p...
متن کاملThe new clearance method for hepatic diagnostics.
New multiparametric analysis and method of their evaluation were derived. The bolus dye injection is used for evaluation of ICG (indicyaningreen) and BSP (bromsulphophtalein) kinetics. This arrangement is a form of spectrophotometric measurement of BSP in plasma and/or pulse dye densitometry of ICG. Clearance values enable to differentiate liver diseases and to add their clinical staging. Patho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Paediatric anaesthesia
دوره 18 9 شماره
صفحات -
تاریخ انتشار 2008