Impacts of Pinhole Images on Image Quality and Interpretation of Pediatric Tc-DMSA Renal Scintigraphy

نویسندگان

  • Shih-Wei Cheng
  • Jih-Hung Chiu
  • Chien-Chin Hsu
  • Shu-Ping Fang
  • Wen-Yuan Chang
  • Chen-Cheng Yang
  • Chi-Yun Chen
چکیده

Received 3/30/2009; revised 4/13/2009; accepted 4/21/2009. For correspondence and reprints contact: Chi-Yun Chen, M.D., Department of Nuclear Medicine, Antai Tian-Sheng Memorial Hospital. 210 Section 1, ChungCheng Road, Tungkang, Pingtung 92842, Taiwan. Tel: (886)8-8329966 ext. 1631, Fax: (886)8-8329977, E-mail: [email protected] Objective: The purpose of this study was to compare the image qualities and interpretations of pediatric Tc-DMSA renal scintigraphy between parallel-hole and pinhole images. Methods: Between Jan 2007 and Dec 2007, 202 pediatric patients (99 boys and 103 girls; age range from 1 month to 14 years old) with urinary tract infection underwent Tc-DMSA renal scintigraphy for diagnosis of acute pyelonephritis (APN). Both of parallel-hole and pinhole images were acquired in all patients. A total of 808 images were assessed by two nuclear medicine specialists. The qualities of images were classified into three grades: poor (blurred renal contour, score 1), fair (clear renal contour but internal architecture not clearly visible, score 2), and good (renal contour and internal architecture clearly visible, score 3). Three categories of image interpretation for APN (negative, equivocal, and positive) were employed. Results: Good agreements within and between the two observers were noted in image quality assessments of parallel-hole images. Excellent and good agreements within and between the two observers, respectively, were noted in image quality assessments of pinhole images. In both of interpretations for parallel-hole and pinhole images, the intraobserver and interobserver agreements by the two observers were excellent and good, respectively. The mean quality scores of parallelhole and pinhole images were 2.10 0.55, 2.40 0.60 by observer A and 2.08 0.50, 2.32 0.58 by observer B, respectively (Wilcoxon test, both P <0.001). Pinhole collimator improved the qualities of DMSA images in 126/404 (31.2%) kidneys (23 poor to fair, 4 poor to good, and 99 fair to good) by observer A and in 111/404 (27.5%) kidneys (21 poor to fair, 3 poor to good, and 87 fair to good) by observer B. With pinhole images, interpretations were changed in 45/404 (11.1%) kidneys (20 negative to equivocal, 18 equivocal to positive, and 7 equivocal to negative) by observer A and in 50/404 (12.4%) kidneys (17 negative to equivocal, 9 equivocal to positive, 21 equivocal to negative, and 3 positive to equivocal) by observer B. Conclusion: Tc-DMSA scintigraphy using pinhole collimator in pediatric patients can improve image qualities in comparison with parallel-hole collimator. The pinhole images also have impacts on the interpretation for APN. Accordingly, we suggest using pinhole collimator in Tc-DMSA scintigraphy for all pediatric patients routinely.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The comparison between ultrasonography and 99mTc-DMSA renal scan in estimation of kidney size

Introduction: Renal length measurement is an important diagnostic clue in several urinary tract abnormalities. Although ultra sonography is the most frequent used modality for renal size estimation, renal diameter assessment by 99mTc-DMSA scintigraphy is of great value. By now, pointing to the renal size in the 99mTc-DMSA scintigraphy report has not been recommended by gui...

متن کامل

Assessment of the maximum uptake time of 99mTc-DMSA in renal scintigraphy in rat

Introduction:The optimal imaging time of a radionuclide scintigraphy is the time at which the organ of interest has the maximum uptake of the injected radionuclide. This study was performed to investigate the maximum uptake time of 99mTc-DMSA in rat renal scan. Methods: Renal scintigraphy was performed with 3 mCi of 99mTc-DMSA. Planar ima...

متن کامل

Technetium-99m-N,N-ethylenedicysteine and Tc-99m DMSA scintigraphy in the evaluation of renal parenchymal abnormalities in children.

UNLABELLED Technetium-99m dimercaptosuccinic acid (Tc-99m DMSA) as a static renal agent is currently the most frequently used agent in the detection of renal scarring, and allows accurate calculation of differential renal function (DRF). But this agent has some disadvantages such as relatively higher radiation dose and time consumption. METHODS The purpose of this study was to evaluate the po...

متن کامل

use of 99m Tc-DMSA scintigraphy in assessment of renal complications of COVID-19

 ABSTRACT COVID-19 mainly affects respiratory and immune systems, but other organs like renal, cardiovascular, lung and nervous systems could also be involved in both acute and chronic settings (1, 2). There is a lot of studies that demonstrate an increasing number of long COVID-19 who continue to experience persistent symptoms weeks or even months after the initial disease. Reports suggest...

متن کامل

Early detection of renal scarring in children with suspected pyelonephritis: Comparison of diuretic MAG3 scintigraphy (F0) and DMSAScan

 Abstract Background: Screening for patients at risk of renal scarring is a challenge in children with acute pyelonephritis (APN). Diuretic Tc-99m mercaptoacetyltriglycine (MAG3) scintigraphy with zero time injection of furosemide (MAG3-F0) was observed to display focal parenchymal disorders. The advantages of MAG3 include: lower radiation dose and short duration of the test. The aim of this st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009