Motion-Compensated Cone Beam CT Using a Conjugate Gradient Least Squares Algorithm and EIT Imaging Motion Data
نویسندگان
چکیده
Cone Beam Computed Tomography (CBCT) is an imaging modality that has been used in image-guided radiation therapy (IGRT). For applications such as lung radiation therapy, CBCT images are greatly affected by the motion artefacts. This is mainly due to low temporal resolution of CBCT. Recently, a dual modality of Electrical Impedance Tomography (EIT) and CBCT has been proposed, in which the high temporal resolution EIT imaging system provides motion data to a motion compensated algebraic reconstruction technique (ART) based CBCT reconstruction software. High computational time associated with ART and indeed other variations of ART make it less practical for real applications. This paper develops a motion-compensated conjugate gradient least squares (CGLS) algorithm for CBCT. A motion-compensated CGLS offers several advantages over ART based methods; including possibilities for: explicit regularisation, rapid convergence, and parallel computations. This paper for the first time demonstrates motion compensated CBCT reconstruction using CGLS and reconstruction results are shown in limited data CBCT considering only a quarter of full data set. The proposed algorithm is tested using simulated motion data in generic motion compensated CBCT as well as measured EIT data in dual EIT-CBCT imaging.
منابع مشابه
A dual modality of cone beam CT and electrical impedance tomography for lung imaging
Electrical impedance tomography (EIT) is a new and emerging tomographic imaging system, which is able to provide high temporal resolution with low spatial resolution. In past few years, the EIT has been extensively studied for lung monitoring. Cone beam CT (CBCT) is an imaging system used in radiation therapy unit. The CBCT suffers from motion artefacts, making treatment planning inaccurate. Th...
متن کاملOn-the-Fly Motion-Compensated Cone-Beam CT Using an a Priori Motion Model
Respiratory motion causes artifacts in slow-rotating cone-beam (CB) computed tomography (CT) images acquired for example for image guidance of radiotherapy. Respiration-correlated CBCT has been proposed to correct for the respiratory motion, but the use of a subset of the CB projections to reconstruct each frame of the 4D CBCT image limits their quality, thus requiring a longer acquisition time...
متن کاملTitle: Breathing motion compensated reconstruction for C-arm cone beam CT imaging: initial experience based on animal data
C-arm based tomographic 3D imaging is applied in an increasing number of minimal invasive procedures. Due to the limited acquisition speed for a complete projection data set required for tomographic reconstruction, breathing motion is a potential source of artifacts. This is the case for patients who cannot comply breathing commands (e.g. due to anesthesia). Intra-scan motion estimation and com...
متن کاملMotion compensated iterative reconstruction of a region of interest in cardiac cone-beam CT
A method for motion compensated iterative CT reconstruction of a cardiac region-of-interest is presented. The algorithm is an ordered subset maximum likelihood approach with spherically symmetric basis functions, and it uses an ECG for gating. Since the straightforward application of iterative methods to CT data has the drawback that a field-of-view has to be reconstructed, which covers the com...
متن کاملMotion-compensated iterative cone-beam CT image reconstruction with adapted blobs as basis functions.
This paper presents a three-dimensional method to reconstruct moving objects from cone-beam X-ray projections using an iterative reconstruction algorithm and a given motion vector field. For the image representation, adapted blobs are used, which can be implemented efficiently as basis functions. Iterative reconstruction requires the calculation of line integrals (forward projections) through t...
متن کامل