BACKGROUND Hypotension is the most common problem with spinal anesthesia. This prospective study aimed to compare normotensive and hypertensive patients with respect to the hemodynamic effects of spinal anesthesia performed with hyperbaric bupivacaine. MATERIAL AND METHODS Sixty patients who were scheduled to undergo various elective operations under spinal anesthesia were included into the study. The patients were separated into 2 groups: hypertensive patients constituted Group H (n=30) and normotensive patients constituted Group N (n=30). After fluid loading, spinal anesthesia was performed with 3.5 ml 0.5% hyperbaric bupivacaine. Demographic characteristics and incidence of hypotension and bradycardia were compared. Systolic (SBP), diastolic (DBP), and mean blood pressures (MBP) and heart rate (HR) were also compared before and after spinal anesthesia. RESULTS There was no significant difference between the groups with respect to demographic characteristics, maximal height of sensory block, incidences of hypotension and bradycardia, and the amount of fluids infused (p>0.05). In the hypertensive patient group, the SBP, DBP, and MBP values were significantly higher than in the normotensive patient group at all measurement times (p<0.05). Comparison within the groups did not reveal any significant differences in either group compared to the basal values (p>0.05). There were no significant differences in HR between or within groups (p>0.05). CONCLUSIONS There was no significant difference between normotensive and hypertensive patients in the incidences of hypotension caused by spinal anesthesia with 0.5% hyperbaric bupivacaine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه‌ی اثر بلوک حس‍ی- حرکت‍ی بوپیواکائین با لیدوکائین دوز پایین و هیپرباریک در جراح‍ی آنورکتال به روش بی‌حس‍ی نخاع‍ی

Background & Objective: Outpatient surgery can be performed by general or spinal anesthesia. Spinal anesthetic drugs have side effects. Many anesthesiologists choose general anesthesia, because of its relative predictability and to avoid undesirable side effects associated with spinal anesthesia. For example lidocaine is frequently associated with Transient Neuroligic Symptoms (TNS). Bupivacain...

متن کامل

بی حسی نخاعی برای عمل جراحی سزارین: مقایسه بوپی واکا یین هیپرباریک با ایزوباریک

Aims and Background: The baricity of the solutions used for spinal anesthesia significantly affects the distribution and dissemination of local anesthetics into the spinal space. The purpose of this study was to compare the effects of hyperbaric and isobaric bupivacaine for spinal anesthesia in cesarean section. Materials and Methods: This was a randomized double blind clinical trial on sixt...

متن کامل

ED50 of hyperbaric bupivacaine with fentanyl for cesarean delivery under combined spinal epidural in normotensive and preeclamptic patients.

BACKGROUND AND OBJECTIVES The use of reduced intrathecal doses is advised for spinal anesthesia during cesarean delivery. However, there are inadequate data regarding the minimum effective dose of intrathecal bupivacaine for cesarean delivery. Preeclampsia is caused by an endothelial dysfunction leading to generalized vasoconstriction. Whether this can offset the pregnancy-induced decrease in i...

متن کامل

Baricity of Bupivacaine on Maternal Hemodynamics after Spinal Anesthesia for Cesarean Section: A Randomized Controlled Trial

Background: After spinal anesthesia, patients undergoing cesarean section are more likely to develop hemodynamic changes. The baricity of local anesthetic has an important role on spinal blockade effects. The aim of this study was to compare the isobar and hyperbaric bupivacaine 0.5% plus fentanyl on maternal hemodynamics after spinal anesthesia for C/S.Methods: In this double-blind study, 84 h...

متن کامل

Intrathecal fentanyl for prevention of shivering in spinal anesthesia in cesarean section

 Background: Shivering is one of the common problems in spinal anesthesia. The objective of the present study was to evaluate the effect of intrathecal fentanyl (25 μg) on incidence and severity of intraoperative and postoperative shivering. Methods: A double-blind randomized controlled study was conducted in eighty healthy women (ASA Physical status I) scheduled for elective cesarean section u...