Porous-coated cementless acetabular components without bulk bone graft in revision surgery.
نویسندگان
چکیده
We previously reported the average 9.3-year (range, 5-13 years) results of 74 patients (83 hips) with porous-coated acetabular components that were placed without bulk bone graft at revision surgery. Since the previous report, 7 patients (7 hips) died before the minimum follow-up of 10 years, and 1 patient (1 hip) was lost to follow-up. We now report the average 15.6-year (range, 10-20 years) results for 66 patients (75 hips). Three additional acetabular components were removed or revised again: 2 for infection and 1 for dislodgement of the polyethylene liner from the metal shell. Overall, 7 (7%) components required removal or repeat revision. No shell was revised for aseptic loosening, and none was categorized as loose during the entire follow-up period.
منابع مشابه
Twenty-year survival of a cementless revision hip arthroplasty using a press-fit bulk acetabular allograft for pelvic discontinuity: a case report.
Acetabular revision in a total hip arthroplasty (THA) with pelvic discontinuity is uncommon and challenging. Optimal management remains controversial, particularly with graft and implant selection. Interpretation of outcomes is confounded by the heterogeneity of patterns of bone loss and the lack of long-term results in great numbers for any given choice of treatment. We report a revision THA u...
متن کاملStructural bulk allografts in acetabular reconstruction. Analysis of two grafts retrieved at post-mortem.
Two acetabula which contained large bone allografts introduced at revision arthroplasty were obtained at post-mortem. The allografts had been placed in superior defects to support cementless acetabular components, and both hips were functioning well at the time of death. Clinical radiographs demonstrated apparent healing of graft to host bone, no graft collapse and stability of the acetabular c...
متن کاملCementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs
Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...
متن کاملTen-year follow-up of the non-porous Allofit cementless acetabular component.
Cementless acetabular fixation has demonstrated superior long-term durability in total hip replacement, but most series have studied implants with porous metal surfaces. We retrospectively evaluated the results of 100 consecutive patients undergoing total hip replacement where a non-porous Allofit component was used for primary press-fit fixation. This implant is titanium alloy, grit-blasted, w...
متن کاملHigh Long-term Survival of Bulk Femoral Head Autograft for Acetabular Reconstruction in Cementless THA for Developmental Hip Dysplasia
BACKGROUND Deficient acetabula associated with acetabular dysplasia cause difficulty achieving adequate coverage of the acetabular component during THA. Autografting with the removed femoral head has been used for several decades to achieve better coverage, but the long-term benefits of this technique remain controversial, with some series reporting high rates of graft resorption and collapse. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of arthroplasty
دوره 25 8 شماره
صفحات -
تاریخ انتشار 2010