In reference to late complications of nickel-titanium alloy stent in tracheal stenosis.

نویسنده

  • Glenn W Knox
چکیده

OBJECTIVES/HYPOTHESIS To investigate and treat the late complications of using nickel-titanium alloy stents in laryngotracheal, bronchial, and esophageal stenosis patients who developed severe laryngotracheal stenosis (SLS). STUDY DESIGN Retrospective clinical study. METHODS Thirteen patients with SLS or tracheoesophageal fistula secondary to insertion of a nickel-titanium alloy stent for treatment of laryngotracheal, bronchial, or esophageal stenosis treated between May 2004 and March 2010 were retrospectively analyzed. Of the 13 total patients, nine had one stent placed, and four had two stents placed. The late complications observed were glottic and/or subglottic extension of cervical tracheal stenosis (n = 6), new stricture of the thoracic trachea (n = 4), severe left bronchial stricture with massive left pulmonary collapse (n = 1), and cervical tracheoesophageal fistula (n = 2). RESULTS Six patients with glottic and/or subglottic to cervical tracheal stenosis underwent successful laryngotracheal reconstruction. Two patients with subglottic and upper thoracic tracheal stenosis were successfully treated by staged operation for the stenosis. Two patients with subglottic and distal thoracic tracheal stenosis are still undergoing treatment. One patient with severe left bronchial stricture and massive left pulmonary collapse has been treated but has not achieved full recovery. One patient with cervical tracheoesophageal fistula underwent successful repair but died later from metastatic disease. One patient with tracheoesophageal fistula died from massive hemorrhage and asphyxiation induced by the stent, which had not been removed. CONCLUSIONS The nickel-titanium alloy stents should be used with extreme caution in patients with laryngotracheal, bronchial, or esophageal stenosis treatment that can be corrected by surgical therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Palliation of terminal malignancy with shape memory alloy ureteric stents.

We report on the first case in Ireland of ureteric stenting with shape-memory alloy nickel-titanium (Memokath 051) stent in relieving malignant ureteric obstruction. Successful drainage was achieved and the patient required no further intervention indicating a clear place for these stents in the long-term management of malignant ureteric strictures. The use of ureteric double-J stenting in the ...

متن کامل

Tracheal T-Tube Stent for Laryngotracheal Stenosis: Ten Year Experience

Introduction: The purpose of this retrospective study was to evaluate the outcome following stenting over a period of 10 years in patients with chronic laryngotracheal stenosis.   Materials and Methods: Between 2000–2010, out of 111 patients with laryngotracheal trauma, 71 underwent tracheal        T-stenting for laryngotracheal stenosis in the Department of Otorhinolaryngology at the Governmen...

متن کامل

Thermo-expandable metallic urethral stents for managing recurrent bulbar urethral strictures: To use or not?

OBJECTIVES To assess the role of temporary thermally expandable urethral stents in maintaining urethral patency in patients with a recurrent bulbar urethral stricture. PATIENTS AND METHODS Twenty-three men with a recurrent bulbar urethral stricture after several attempts at direct visual internal urethrotomy (DVIU) and/or failed urethroplasty were managed with a thermally expandable, biocompa...

متن کامل

Fabrication of Spiral Stent with Superelastic/ Shape Memory Nitinol Alloy for Femoral Vessel

Stent is a metal mesh tube for opening the obstructed vessels of the body. Ni-Ti alloy is a suitable metal for fabrication of stent due to its potential for applying the appropriate stress and strain to the vessel walls. In this study, super-elastic Nitinol wire was used to build stent samples usable to open femoral vessel. Ageing was performed at 500°C for different periods of time to determin...

متن کامل

Thermo-mechanical behavior of shape memory alloy made stent- graft by multi-plane model

Constitutive law for shape-memory alloys subjected to multi-axial loading, which is based on a semi-micromechanical integrated multi-plane model capable of internal mechanism observations, is generally not available in the literature. The presented numerical results show significant variations in the mechanical response along the multi loading axes. These are attributed to changes in the marten...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Laryngoscope

دوره 123 2  شماره 

صفحات  -

تاریخ انتشار 2012