Endemic contamination of clinical specimens by Mycobacterium gordonae.
نویسندگان
چکیده
Contamination of clinical specimens by Mycobacterium gordonae is a significant endemic problem in many laboratories. To investigate this problem, 84 cases at 1 hospital were retrospectively identified during 20 months. The overall rate of specimen contamination was 2. 4%, and 72 of the contaminated specimens were respiratory. A case-control comparison showed that the risk of respiratory specimen contamination was significantly increased if the specimen was expectorated (odds ratio [OR], 3.62; 95% confidence interval [CI], 1. 36-9.50) or if the patient consumed fluids within 2 days before specimen collection (OR, 8.92; 95% CI, 1.40-71.20). Cultures of tap water, ice, and iced drinking water all yielded M. gordonae at 10(-2)-10(0) cfu/mL. A culture survey of consenting patients showed contamination of 8 (24%) of 34 sputum specimens collected immediately after a tap water mouth rinse. These findings demonstrate that endemic specimen contamination arises from mycobacteria in hospital tap water and provide a foundation for control efforts.
منابع مشابه
Mycobacterium gordonae pseudoinfection associated with a contaminated antimicrobial solution.
At Yale-New Haven Hospital, 46 specimens submitted for mycobacterial culture during an 8-week period in 1989 were positive for Mycobacterium gordonae, a nontuberculous acid-fast bacterium (AFB) of low pathogenicity. The specimens were submitted from 34 patients who came from various inpatient and outpatient services. Four patients were begun on antimycobacterial therapy on the basis of an AFB i...
متن کاملComparison of the BACTEC MGIT 960 and ESP culture system II for growth and detection of mycobacteria.
The performances of two continuously monitoring mycobacterial culture systems-ESP Culture System II (ESP II; Trek Diagnostics, Inc. , Westlake, Ohio) and BACTEC MGIT 960 (BD Biosciences, Sparks, Md. )-were compared. In addition to both liquid media, all specimens were plated onto Middlebrook 7H11/7H11 selective agar. A total of 3, 151 specimens of all types (56.3% were respiratory specimens) we...
متن کاملSensitivity of fluorochrome microscopy for detection of Mycobacterium tuberculosis versus nontuberculous mycobacteria.
The results for 6,532 consecutive mycobacterial respiratory specimens collected from 1,040 patients from 1993 to 1995 in a Texas hospital were studied to determine the sensitivity of fluorescence microscopy for detection of Mycobacterium tuberculosis and nontuberculous mycobacteria (NTM). Smears were positive for acid-fast bacilli (AFB) in 63% (677 of 1,082) of specimens growing M. tuberculosis...
متن کاملUse of Gen-Probe AccuProbes to identify Mycobacterium avium complex, Mycobacterium tuberculosis complex, Mycobacterium kansasii, and Mycobacterium gordonae directly from BACTEC TB broth cultures.
To evaluate the utility of Gen-Probe AccuProbes for the identification of mycobacteria directly from BACTEC TB 12B vials containing acid-fast bacilli, culture results for 11,375 clinical specimens other than blood received from 1 January 1992 to 30 September 1993 were reviewed retrospectively. During this period, a total of 359 of 11,375 BACTEC vials were positive for acid-fast bacilli and were...
متن کاملDisinfection of the flexible fibreoptic bronchoscope against Mycobacterium tuberculosis and M gordonae.
In view of recent reports of contamination of the fibreoptic bronchoscope by tuberculous and non-tuberculous mycobacteria, we evaluated the disinfecting properties of aqueous glutaraldehyde (Cidex) and an iodophor (Prepodyne) against Mycobacterium tuberculosis and M gordonae. We found that a 15 minute disinfection procedure with either agent, coupled with initial vigorous mechanical cleaning of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical infectious diseases : an official publication of the Infectious Diseases Society of America