Surface changes of metal alloys and high-strength ceramics after ultrasonic scaling and intraoral polishing
نویسندگان
چکیده
PURPOSE This study was to evaluate the effect of repeated ultrasonic scaling and surface polishing with intraoral polishing kits on the surface roughness of three different restorative materials. MATERIALS AND METHODS A total of 15 identical discs were fabricated with three different materials. The ultrasonic scaling was conducted for 20 seconds on the test surfaces. Subsequently, a multi-step polishing with recommended intraoral polishing kit was performed for 30 seconds. The 3D profiler and scanning electron microscopy were used to investigate surface integrity before scaling (pristine), after scaling, and after surface polishing for each material. Non-parametric Friedman and Wilcoxon signed rank sum tests were employed to statistically evaluate surface roughness changes of the pristine, scaled, and polished specimens. The level of significance was set at 0.05. RESULTS Surface roughness values before scaling (pristine), after scaling, and polishing of the metal alloys were 3.02±0.34 µm, 2.44±0.72 µm, and 3.49±0.72 µm, respectively. Surface roughness of lithium disilicate increased from 2.35±1.05 µm (pristine) to 28.54±9.64 µm (scaling), and further increased after polishing (56.66±9.12 µm, P<.05). The zirconia showed the most increase in roughness after scaling (from 1.65±0.42 µm to 101.37±18.75 µm), while its surface roughness decreased after polishing (29.57±18.86 µm, P<.05). CONCLUSION Ultrasonic scaling significantly changed the surface integrities of lithium disilicate and zirconia. Surface polishing with multi-step intraoral kit after repeated scaling was only effective for the zirconia, while it was not for lithium disilicate.
منابع مشابه
بررسی تأثیر سه روش آمادهسازی سطح در باند بین آلیاژهای بیسمتال و ماده (Targis) Ceromer
Statement of Problem: Ceramics and resins belong to the earliest tooth restorative materials. Nowadays new generations of these materials have provided a revolution in cosmetic dentistry. Ceramic Optimized polymer (Ceromer) is a newly made product that the bond between this material and base metal alloys, which are used widely today, is paid too much attention. Purpose: The aim of this study wa...
متن کاملClassifications and Properties of Materials for Chairside Computer-Aided Design/Computer-Aided Manufacturing Dentistry: A Review
Background and Aim: Chairside computer-aided design/computer-aided manufacturing (CAD/CAM) systems have become considerably more accurate, reliable, efficient, fast, and prevalent since 1985 when CEREC was introduced. The inceptive restorative material option for chairside CAD/CAM restorations was limited to ceramic blocks. Today, restorative material options have been multiplied and include me...
متن کاملبررسی اثر پخت مکرر پرسلن بر مقاومت باند در دو نوع آلیاژ بیس متال (مینالوکس و وراباند 2)
The formation of oxides on the surface of the metal are proven to contribute to the formation of strong bonding. However, The base metal alloys are expected to exhibit more oxidation than high gold alloys, increase in oxide layer thickness due to repeated firing in them can reduce the bond strength. The aim of this study was to compare the effect of repeated porcelain firing on the bond strengt...
متن کاملFATIGUE BEHAVIOUR OFA ROLLED AZ31 MAGNESIUM ALLOYS PREPARED BY EPAND BB CONDITIONS
Abstract: Rotating bending fatigue tests have been performed using smooth specimens of a rolled AZ31 magnesium alloy in laboratory air at ambient temperature. Fatigue strength and characteristic was evaluated and fracture mechanism was discussed on the basis fracture surface analysis. Electrical polishing (EP) as well as deep rolling (ball burnishing (BB)) U-notched specimens were performed on ...
متن کاملبررسی و مقایسه زیستسازگاری آلیاژ مینالوکس و آلیاژ مشابه خارجی (In-vitro)
Statement of Problem: One of newly presented base metal alloys (Minalux) is produced according to VeraBond2 alloy (Ni- Cr base) composition. Several studies showed that, cytotoxicity of base metal alloys can be occurred due to corrosion and element release. Purpose: This study evaluated the biocompatibility of these two base metal alloys in three steps: as cast, after polishing and after porcel...
متن کامل